Name |
Description |
|
AngleFund
|
Value of the power angle at fundamental frequency.
|
|
ANSITDF
|
Transformer derating factor.
|
|
ArithSum
|
Arithmetic sum.
|
|
AvgImbal
|
Imbalance by max deviation from average.
|
|
CrestFactor
|
Crest factor.
|
|
DAxis
|
D axis components.
|
|
DAxisField
|
D axis components.
|
|
DF
|
Displacement factor - Cosine of the phase angle between fundamental frequency voltage and current phasors.
|
|
DFArith
|
Displacement factor - IEEE arithmetic calculations.
|
|
DFCoSDemand
|
Value of displacement power factor coincident with apparent power demand.
|
|
DFDemand
|
Value of displacement power factor for a demand interval.
|
|
DFVector
|
Displacement factor - IEEE vector calculations.
|
|
EvenTHD
|
Even harmonic distortion (%).
|
|
EvenTHDRMS
|
Even THD normalized to RMS.
|
|
FlkrFreqMax
|
Frequence of maximum flicker harmonic.
|
|
FlkrMagAvg
|
Flicker average RMS value.
|
|
FlkrMagMax
|
Magnitude of maximum flicker harmonic.
|
|
FlkrMaxDVV
|
dV/V base.
|
|
FlkrPiLPF
|
Pi LPF.
|
|
FlkrPiMax
|
Pi max.
|
|
FlkrPiRoot
|
Pi root.
|
|
FlkrPiRootLPF
|
Pi root LPF.
|
|
FlkrPLT
|
Long term flicker.
|
|
FlkrPLTSlide
|
Sliding PLT.
|
|
FlkrPST
|
Short term flicker.
|
|
FlkrSpectrum
|
Flicker spectrum VRMS(F).
|
|
FlkrWgtAvg
|
Spectrum weighted average.
|
|
FormFactor
|
Form factor.
|
|
Frequency
|
Frequency.
|
|
HRMS
|
Harmonic RMS.
|
|
IHRMS
|
Interharmonic RMS.
|
|
Instantaneous
|
Instantaneous f(t).
|
|
IT
|
IT.
|
|
KFactor
|
Transformer K factor.
|
|
Linear
|
Linear position.
|
|
None
|
No quantity characteristic.
|
|
OddTHD
|
Odd harmonic distortion (%).
|
|
OddTHDRMS
|
Odd THD normalized to RMS.
|
|
P
|
Real power (watts).
|
|
PCoQDemand
|
Value of active power coincident with reactive power demand.
|
|
PCoSDemand
|
Value of active power coincident with apparent power demand.
|
|
PDemand
|
Value of active power for a demand interval.
|
|
Peak
|
Peak value.
|
|
PF
|
True power factor - (Vrms * Irms) / P.
|
|
PFArith
|
True power factor - IEEE arithmetic calculations.
|
|
PFCoPDemand
|
Value of true power factor coincident with active power demand.
|
|
PFCoQDemand
|
Value of true power factor coincident with reactive power demand.
|
|
PFCoSDemand
|
Value of true power factor coincident with apparent power demand.
|
|
PFDemand
|
Value of true power factor for a demand interval.
|
|
PFund
|
Value of fundamental frequency real power.
|
|
PFVector
|
True power factor - IEEE vector calculations.
|
|
PHarmonic
|
Net harmonic active power.
|
|
PHarmonicUnsigned
|
Arithmetic sum harmonic active power.
|
|
PIntg
|
Value of active power integrated over time (Energy - watt-hours).
|
|
PIntgNeg
|
Value of active power integrated over time (Energy - watt-hours) in the negative direction (away from load).
|
|
PIntgNegFund
|
Value of active fundamental frequency power integrated over time
(Energy - watt-hours) in the negative direction (away from load).
|
|
PIntgPos
|
Value of active power integrated over time (Energy - watt-hours) in the positive direction (toward load).
|
|
PIntgPosFund
|
Value of active fundamental frequency power integrated over time
(Energy - watt-hours) in the positive direction (toward load).
|
|
PIVLIntg
|
Value of active power integrated over time (Energy - watt-hours).
|
|
PIVLIntgNeg
|
Value of active power integrated over time (Energy - watt-hours) in the negative direction (away from load).
|
|
PIVLIntgNegFund
|
Value of active fundamental frequency power integrated over time
(Energy - watt-hours) in the negative direction (away from load).
|
|
PIVLIntgPos
|
Value of active power integrated over time (Energy - watt-hours) in the positive direction (toward load).
|
|
PIVLIntgPosFund
|
Value of active fundamental frequency power integrated over time
(Energy - watt-hours) in the positive direction (toward load).
|
|
PPeakDemand
|
Peak active power demand.
|
|
PPredDemand
|
Predicted value of active power for current demand interval.
|
|
Q
|
Reactive power (VAR).
|
|
QAxis
|
Q axis components.
|
|
QCoPDemand
|
Value of reactive power coincident with active power demand.
|
|
QCoSDemand
|
Value of reactive power coincident with apparent power demand.
|
|
QDemand
|
Value of reactive power for a demand interval.
|
|
QFund
|
Value of the reactive power at fundamental frequency.
|
|
QIntg
|
Value of reactive power integrated over time (var-hours).
|
|
QIntgNeg
|
Value of reactive power integrated over time (Energy - watt-hours) in the negative direction (away from load).
|
|
QIntgNegFund
|
Value of fundamental frequency reactive power integrated over time
(Energy - watt-hours) in the negative direction (away from load).
|
|
QIntgPos
|
Value of reactive power integrated over time (Energy - watt-hours) in the positive direction (toward load).
|
|
QIntgPosFund
|
Value of fundamental frequency reactive power integrated over time
(Energy - watt-hours) in the positive direction (toward load).
|
|
QIVLIntg
|
Value of reactive power integrated over time (var-hours).
|
|
QIVLIntgNeg
|
Value of reactive power integrated over time (Energy - watt-hours) in the negative direction (away from load).
|
|
QIVLIntgNegFund
|
Value of fundamental frequency reactive power integrated over time
(Energy - watt-hours) in the negative direction (away from load).
|
|
QIVLIntgPos
|
Value of reactive power integrated over time (Energy - watt-hours) in the positive direction (toward load).
|
|
QIVLIntgPosFund
|
Value of fundamental frequency reactive power integrated over time
(Energy - watt-hours) in the positive direction (toward load).
|
|
QPeakDemand
|
Peak reactive power demand.
|
|
QPredDemand
|
Predicted value of reactive power for current demand interval.
|
|
RMS
|
RMS value.
|
|
RMSDemand
|
RMS value of current for a demand interval.
|
|
RMSPeakDemand
|
Peak demand current.
|
|
Rotational
|
Rotational position.
|
|
S
|
Apparent power (VA).
|
|
S0S1
|
Zero sequence component unbalance (%).
|
|
S2S1
|
Negative sequence component unbalance (%).
|
|
SArith
|
Value of apparent power - IEEE arithmetic calculations.
|
|
SArithFund
|
Value of fundamental frequency apparent power - IEEE arithmetic calculations.
|
|
SCoPDemand
|
Apparent power coincident with active power demand.
|
|
SCoQDemand
|
Apparent power coincident with reactive power demand.
|
|
SDemand
|
Value of apparent power for a demand interval.
|
|
SFund
|
Value of fundamental frequency apparent power.
|
|
SIntg
|
Value of apparent power integrated over time (VA-hours).
|
|
SIntgFund
|
Value of fundamental frequency apparent power integrated over time (VA-hours).
|
|
SIVLIntg
|
Value of apparent power integrated over time (VA-hours).
|
|
SIVLIntgFund
|
Value of fundamental frequency apparent power integrated over time (VA-hours).
|
|
SNeg
|
Negative sequence component.
|
|
SPeakDemand
|
Peak apparent power demand.
|
|
Spectra
|
Spectra F(F).
|
|
SpectraHGroup
|
Spectra by harmonic group index.
|
|
SpectraIGroup
|
Spectra by interharmonic group index.
|
|
SPos
|
Positive sequence component.
|
|
SPredDemand
|
Predicted value of apparent power for current demand interval.
|
|
Status
|
Status data.
|
|
SVector
|
Value of apparent power - IEEE vector calculations.
|
|
SVectorFund
|
Value of fundamental frequency apparent power - IEEE vector calculations.
|
|
SZero
|
Zero sequence component.
|
|
TDD
|
Total demand distortion.
|
|
TID
|
Total interharmonic distortion.
|
|
TIDRMS
|
Total interharmonic distortion normalized to RMS.
|
|
TIF
|
TIF.
|
|
TIFRMS
|
TIF normalized to RMS.
|
|
TotalTHD
|
Total harmonic distortion (%).
|
|
TotalTHDRMS
|
Total THD normalized to RMS.
|
|
TransferFunc
|
Transfer function.
|