-- Script auto-generated generated from Access database openPG.mdb method GenerateSampleDataScript -- 7/8/2010 1:09:58 PM USE openPG GO INSERT INTO Node(Name, CompanyID, Description, Settings, MenuType, MenuData, Master, LoadOrder, Enabled) VALUES('Default', NULL, 'Default node', 'RemoteStatusServerConnectionString={server=localhost:8505};datapublisherport=6170;RealTimeStatisticServiceUrl=http://localhost:6054/historian;AlarmServiceUrl=http://localhost:5019/alarmservices', 'File', 'Menu.xml', 1, 0, 1) UPDATE Node SET ID='d1ebffbb-d318-463f-9822-394fd0e968b0' WHERE Name='Default' INSERT INTO Historian(NodeID, Acronym, Name, AssemblyName, TypeName, ConnectionString, IsLocal, Description, LoadOrder, Enabled) VALUES('d1ebffbb-d318-463f-9822-394fd0e968b0', 'DEVARCHIVE', 'Local Development Archive', 'HistorianAdapters.dll', 'HistorianAdapters.LocalOutputAdapter', '', 1, 'Local development archive', 0, 1) INSERT INTO Device(NodeID, Acronym, Name, IsConcentrator, CompanyID, HistorianID, AccessID, VendorDeviceID, ProtocolID, Longitude, Latitude, InterconnectionID, ConnectionString, MeasuredLines, LoadOrder, Enabled) VALUES('d1ebffbb-d318-463f-9822-394fd0e968b0', 'TESTDEVICE', 'Test Device', 0, 30, 1, 2, 2, 3, -89.8038, 35.3871, 1, 'transportProtocol=File; file=Sample1344.PmuCapture; useHighResolutionInputTimer=True', 3, 0, 1) INSERT INTO Phasor(DeviceID, Label, Type, Phase, SourceIndex) VALUES(1, '500 kV Bus 1', 'V', '+', 1) INSERT INTO Phasor(DeviceID, Label, Type, Phase, SourceIndex) VALUES(1, '500 kV Bus 2', 'V', '+', 2) INSERT INTO Phasor(DeviceID, Label, Type, Phase, SourceIndex) VALUES(1, 'Cordova', 'I', '+', 3) INSERT INTO Phasor(DeviceID, Label, Type, Phase, SourceIndex) VALUES(1, 'Dell', 'I', '+', 4) INSERT INTO Phasor(DeviceID, Label, Type, Phase, SourceIndex) VALUES(1, 'Lagoon Creek', 'I', '+', 5) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE:ABBS', 8, NULL, 'TESTDEVICE-SF', 'Test Device ABB-521 Status Flags', 1) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE:ABBF', 5, NULL, 'TESTDEVICE-FQ', 'Test Device ABB-521 Frequency', 1) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE:ABBD1', 9, NULL, 'TESTDEVICE-DV1', 'Test Device ABB-521 Digital Value 1', 1) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE:ABBDF', 6, NULL, 'TESTDEVICE-DF', 'Test Device ABB-521 Frequency Delta (dF/dt)', 1) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-BUS1:ABBV', 3, 1, 'TESTDEVICE-PM1', 'Test Device ABB-521 500 kV Bus 1 Positive Sequence Voltage Magnitude', 1) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-BUS1:ABBVH', 4, 1, 'TESTDEVICE-PA1', 'Test Device ABB-521 500 kV Bus 1 Positive Sequence Voltage Phase Angle', 1) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-BUS2:ABBV', 3, 2, 'TESTDEVICE-PM2', 'Test Device ABB-521 500 kV Bus 2 Positive Sequence Voltage Magnitude', 1) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-BUS2:ABBVH', 4, 2, 'TESTDEVICE-PA2', 'Test Device ABB-521 500 kV Bus 2 Positive Sequence Voltage Phase Angle', 1) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-CORD:ABBI', 1, 3, 'TESTDEVICE-PM3', 'Test Device ABB-521 Cordova Positive Sequence Current Magnitude', 1) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-CORD:ABBIH', 2, 3, 'TESTDEVICE-PA3', 'Test Device ABB-521 Cordova Positive Sequence Current Phase Angle', 1) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-DELL:ABBI', 1, 4, 'TESTDEVICE-PM4', 'Test Device ABB-521 Dell Positive Sequence Current Magnitude', 1) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-DELL:ABBIH', 2, 4, 'TESTDEVICE-PA4', 'Test Device ABB-521 Dell Positive Sequence Current Phase Angle', 1) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-LAGO:ABBI', 1, 5, 'TESTDEVICE-PM5', 'Test Device ABB-521 Lagoon Creek Positive Sequence Current Magnitude', 1) INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-LAGO:ABBIH', 2, 5, 'TESTDEVICE-PA5', 'Test Device ABB-521 Lagoon Creek Positive Sequence Current Phase Angle', 1) INSERT INTO ApplicationRole (Name, Description, NodeID) VALUES ('Administrator', 'Administrator Role', 'd1ebffbb-d318-463f-9822-394fd0e968b0') INSERT INTO ApplicationRole (Name, Description, NodeID) VALUES ('Editor', 'Editor', 'd1ebffbb-d318-463f-9822-394fd0e968b0') INSERT INTO ApplicationRole (Name, Description, NodeID) VALUES ('Viewer', 'Viewer Role', 'd1ebffbb-d318-463f-9822-394fd0e968b0')