-- ---------------------------------------------------------------------------------------------------- -- openPDC Data Structures for SQL Server - Gbtc -- -- Copyright © 2011, Grid Protection Alliance. All Rights Reserved. -- -- Licensed to the Grid Protection Alliance (GPA) under one or more contributor license agreements. See -- the NOTICE file distributed with this work for additional information regarding copyright ownership. -- The GPA licenses this file to you under the MIT License (MIT), the "License"; you may -- not use this file except in compliance with the License. You may obtain a copy of the License at: -- -- http://www.opensource.org/licenses/MIT -- -- Unless agreed to in writing, the subject software distributed under the License is distributed on an -- "AS-IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. Refer to the -- License for the specific language governing permissions and limitations. -- -- Schema Modification History: -- ---------------------------------------------------------------------------------------------------- -- 05/07/2011 - J. Ritchie Carroll -- Generated original version of schema. -- 05/23/2011 - Mehulbhai P Thakkar -- Script is based on openPDC.sql script created by James Ritchie Carroll. -- 03/27/2012 - prasanthgs -- Added ExceptionLog table for keeping recent exceptions. -- 04/12/2012 - prasanthgs -- Reworked as per the comments of codeplex reviewers. -- Added new field Type to ErrorLog table. Removed ExceptionLog table. -- ---------------------------------------------------------------------------------------------------- -- ******************************************************************************************* -- IMPORTANT NOTE: When making updates to this schema, please increment the version number! -- -- Search for: -- CREATE VIEW [dbo].[SchemaVersion] AS -- SELECT 1 AS VersionNumber -- GO -- ******************************************************************************************* USE [master] GO CREATE DATABASE [openPDC]; GO ALTER DATABASE [openPDC] SET ANSI_NULL_DEFAULT OFF GO ALTER DATABASE [openPDC] SET ANSI_NULLS OFF GO ALTER DATABASE [openPDC] SET ANSI_PADDING OFF GO ALTER DATABASE [openPDC] SET ANSI_WARNINGS OFF GO ALTER DATABASE [openPDC] SET ARITHABORT OFF GO ALTER DATABASE [openPDC] SET AUTO_CLOSE OFF GO ALTER DATABASE [openPDC] SET AUTO_CREATE_STATISTICS ON GO ALTER DATABASE [openPDC] SET AUTO_SHRINK OFF GO ALTER DATABASE [openPDC] SET AUTO_UPDATE_STATISTICS ON GO ALTER DATABASE [openPDC] SET CURSOR_CLOSE_ON_COMMIT OFF GO ALTER DATABASE [openPDC] SET CURSOR_DEFAULT GLOBAL GO ALTER DATABASE [openPDC] SET CONCAT_NULL_YIELDS_NULL OFF GO ALTER DATABASE [openPDC] SET NUMERIC_ROUNDABORT OFF GO ALTER DATABASE [openPDC] SET QUOTED_IDENTIFIER OFF GO ALTER DATABASE [openPDC] SET RECURSIVE_TRIGGERS OFF GO ALTER DATABASE [openPDC] SET ENABLE_BROKER GO ALTER DATABASE [openPDC] SET AUTO_UPDATE_STATISTICS_ASYNC OFF GO ALTER DATABASE [openPDC] SET DATE_CORRELATION_OPTIMIZATION OFF GO ALTER DATABASE [openPDC] SET TRUSTWORTHY OFF GO ALTER DATABASE [openPDC] SET ALLOW_SNAPSHOT_ISOLATION OFF GO ALTER DATABASE [openPDC] SET PARAMETERIZATION SIMPLE GO ALTER DATABASE [openPDC] SET READ_WRITE GO ALTER DATABASE [openPDC] SET RECOVERY SIMPLE GO ALTER DATABASE [openPDC] SET MULTI_USER GO ALTER DATABASE [openPDC] SET PAGE_VERIFY CHECKSUM GO ALTER DATABASE [openPDC] SET DB_CHAINING OFF GO -- The next three commented statements are used to create a user with access to the openPDC database. -- Be sure to change the username and password. -- Replace-all from NewUser to the desired username is the preferred method of changing the username. --IF NOT EXISTS (SELECT * FROM sys.server_principals WHERE name = N'NewUser') --CREATE LOGIN [NewUser] WITH PASSWORD=N'MyPassword', DEFAULT_DATABASE=[master], CHECK_EXPIRATION=OFF, CHECK_POLICY=OFF --GO USE [openPDC] GO --CREATE USER [NewUser] FOR LOGIN [NewUser] --GO --CREATE ROLE [openPDCManagerRole] AUTHORIZATION [dbo] --GO --EXEC sp_addrolemember N'openPDCManagerRole', N'NewUser' --GO --EXEC sp_addrolemember N'db_datareader', N'openPDCManagerRole' --GO --EXEC sp_addrolemember N'db_datawriter', N'openPDCManagerRole' --GO -- ******************************************************************************************* -- IMPORTANT NOTE: When making updates to this schema, please increment the version number! -- ******************************************************************************************* CREATE VIEW [dbo].[SchemaVersion] AS SELECT 14 AS VersionNumber GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[ErrorLog]( [ID] [int] IDENTITY(1,1) NOT NULL, [Source] [varchar](200) COLLATE SQL_Latin1_General_CP1_CI_AS NOT NULL, [Type] [varchar](max) COLLATE SQL_Latin1_General_CP1_CI_AS NULL, [Message] [varchar](max) COLLATE SQL_Latin1_General_CP1_CI_AS NOT NULL, [Detail] [varchar](max) COLLATE SQL_Latin1_General_CP1_CI_AS NULL, [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_ErrorLog_CreatedOn] DEFAULT (getutcdate()), CONSTRAINT [PK_ErrorLog] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO CREATE TABLE [dbo].[Runtime]( [ID] [int] IDENTITY(1,1) NOT NULL, [SourceID] [int] NOT NULL, [SourceTable] [varchar](200) NOT NULL, CONSTRAINT [PK_Runtime] PRIMARY KEY CLUSTERED ( [SourceID] ASC, [SourceTable] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO CREATE UNIQUE NONCLUSTERED INDEX [IX_Runtime] ON [dbo].[Runtime] ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[AuditLog]( [ID] [int] IDENTITY(1,1) NOT NULL, [TableName] [varchar](200) NOT NULL, [PrimaryKeyColumn] [varchar](200) NOT NULL, [PrimaryKeyValue] [varchar](max) NOT NULL, [ColumnName] [varchar](200) NOT NULL, [OriginalValue] [varchar](max) NULL, [NewValue] [varchar](max) NULL, [Deleted] [bit] NOT NULL CONSTRAINT [DF_AuditLog_Deleted] DEFAULT ((0)), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_AuditLog_UpdatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_AuditLog_UpdatedOn] DEFAULT (getutcdate()), CONSTRAINT [PK_AuditLog] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[Company]( [ID] [int] IDENTITY(1,1) NOT NULL, [Acronym] [varchar](200) NOT NULL, [MapAcronym] [nchar](10) NOT NULL, [Name] [varchar](200) NOT NULL, [URL] [varchar](max) NULL, [LoadOrder] [int] NOT NULL CONSTRAINT [DF_Company_LoadOrder] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_Company_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Company_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_Company_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Company_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_Company] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[TrackedChange]( [ID] [bigint] IDENTITY(1,1) NOT NULL, [TableName] [varchar](200) NOT NULL, [PrimaryKeyColumn] [varchar](200) NOT NULL, [PrimaryKeyValue] [varchar](max) NULL, CONSTRAINT [PK_TrackedChange] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[ConfigurationEntity]( [SourceName] [varchar](200) NOT NULL, [RuntimeName] [varchar](200) NOT NULL, [Description] [varchar](max) NULL, [LoadOrder] [int] NOT NULL CONSTRAINT [DF_ConfigurationEntity_LoadOrder] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_ConfigurationEntity_Enabled] DEFAULT ((0)) ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[Vendor]( [ID] [int] IDENTITY(1,1) NOT NULL, [Acronym] [varchar](200) NULL, [Name] [varchar](200) NOT NULL, [PhoneNumber] [varchar](200) NULL, [ContactEmail] [varchar](200) NULL, [URL] [varchar](max) NULL, [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_Vendor_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Vendor_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_Vendor_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Vendor_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_Vendor] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[Protocol]( [ID] [int] IDENTITY(1,1) NOT NULL, [Acronym] [varchar](200) NOT NULL, [Name] [varchar](200) NOT NULL, [Type] [varchar](200) NOT NULL CONSTRAINT [DF_Protocol_Type] DEFAULT (N'Frame'), [Category] [varchar](200) NOT NULL CONSTRAINT [DF_Protocol_Category] DEFAULT (N'Phasor'), [AssemblyName] [varchar] (1024) NOT NULL CONSTRAINT [DF_Protocol_AssemblyName] DEFAULT (N'PhasorProtocolAdapters.dll'), [TypeName] [varchar] (200) NOT NULL CONSTRAINT [DF_Protocol_TypeName] DEFAULT (N'PhasorProtocolAdapters.PhasorMeasurementMapper'), [LoadOrder] [int] NOT NULL CONSTRAINT [DF_Protocol_LoadOrder] DEFAULT ((0)), CONSTRAINT [PK_Protocol] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[SignalType]( [ID] [int] IDENTITY(1,1) NOT NULL, [Name] [varchar](200) NOT NULL, [Acronym] [varchar](4) NOT NULL, [Suffix] [varchar](2) NOT NULL, [Abbreviation] [varchar](2) NOT NULL, [LongAcronym] [varchar](200) NOT NULL DEFAULT 'Undefined', [Source] [varchar](10) NOT NULL, [EngineeringUnits] [varchar](10) NULL, CONSTRAINT [PK_SignalType] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[Interconnection]( [ID] [int] IDENTITY(1,1) NOT NULL, [Acronym] [varchar](50) NOT NULL, [Name] [varchar](100) NOT NULL, [LoadOrder] [int] NULL CONSTRAINT [DF_Interconnection_LoadOrder] DEFAULT ((0)), CONSTRAINT [PK_Interconnection] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[OtherDevice]( [ID] [int] IDENTITY(1,1) NOT NULL, [Acronym] [varchar](200) NOT NULL, [Name] [varchar](200) NULL, [IsConcentrator] [bit] NOT NULL CONSTRAINT [DF_OtherDevices_IsConcentrator] DEFAULT ((0)), [CompanyID] [int] NULL, [VendorDeviceID] [int] NULL, [Longitude] [decimal](9, 6) NULL, [Latitude] [decimal](9, 6) NULL, [InterconnectionID] [int] NULL, [Planned] [bit] NOT NULL CONSTRAINT [DF_OtherDevices_Planned] DEFAULT ((0)), [Desired] [bit] NOT NULL CONSTRAINT [DF_OtherDevices_Desired] DEFAULT ((0)), [InProgress] [bit] NOT NULL CONSTRAINT [DF_OtherDevices_InProgress] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_OtherDevice_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OtherDevice_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_OtherDevice_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OtherDevice_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_OtherDevice] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[Node]( [ID] [uniqueidentifier] NOT NULL CONSTRAINT [DF_Node_ID] DEFAULT (newid()), [Name] [varchar](200) NOT NULL, [CompanyID] [int] NULL, [Longitude] [decimal](9, 6) NULL, [Latitude] [decimal](9, 6) NULL, [Description] [varchar](max) NULL, [ImagePath] [varchar](max) NULL, [Settings] [varchar] (max) NULL, [MenuType] [varchar] (200) NOT NULL CONSTRAINT [DF_Node_MenuType] DEFAULT (N'File'), [MenuData] [varchar](max) NOT NULL CONSTRAINT [DF_Node_MenuData] DEFAULT (N'Menu.xml'), [Master] [bit] NOT NULL CONSTRAINT [DF_Node_Master] DEFAULT ((0)), [LoadOrder] [int] NOT NULL CONSTRAINT [DF_Node_LoadOrder] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_Node_Enabled] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_Node_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Node_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_Node_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Node_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_Node] PRIMARY KEY NONCLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO CREATE UNIQUE NONCLUSTERED INDEX [IX_Node_Name] ON [dbo].[Node] ( [Name] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] GO CREATE TRIGGER [dbo].[Node_AllMeasurementsGroup] ON [dbo].[Node] AFTER INSERT AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; INSERT INTO MeasurementGroup(NodeID, Name, Description, FilterExpression) SELECT ID, 'AllMeasurements', 'All measurements defined in ActiveMeasurements', 'FILTER ActiveMeasurements WHERE SignalID IS NOT NULL' FROM inserted END SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[DataOperation]( [NodeID] [uniqueidentifier] NULL, [Description] [varchar](max) NULL, [AssemblyName] [varchar](max) NOT NULL, [TypeName] [varchar](max) NOT NULL, [MethodName] [varchar](200) NOT NULL, [Arguments] [varchar](max) NULL, [LoadOrder] [int] NOT NULL CONSTRAINT [DF_DataOperation_LoadOrder] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_DataOperation_Enabled] DEFAULT ((0)) ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[Device]( [NodeID] [uniqueidentifier] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [ParentID] [int] NULL, [UniqueID] [uniqueidentifier] NOT NULL CONSTRAINT [DF_Device_UniqueID] DEFAULT (newid()), [Acronym] [varchar](200) NOT NULL, [Name] [varchar](200) NULL, [OriginalSource] [varchar](200) NULL, [IsConcentrator] [bit] NOT NULL CONSTRAINT [DF_Device_IsConcentrator] DEFAULT ((0)), [CompanyID] [int] NULL, [HistorianID] [int] NULL, [AccessID] [int] NOT NULL CONSTRAINT [DF_Device_AccessID] DEFAULT ((0)), [VendorDeviceID] [int] NULL, [ProtocolID] [int] NULL, [Longitude] [decimal](9, 6) NULL, [Latitude] [decimal](9, 6) NULL, [InterconnectionID] [int] NULL, [ConnectionString] [varchar](max) NULL, [TimeZone] [varchar](200) NULL, [FramesPerSecond] [int] NULL CONSTRAINT [DF_Device_FramesPerSecond] DEFAULT ((30)), [TimeAdjustmentTicks] [bigint] NOT NULL CONSTRAINT [DF_Device_TimeAdjustmentTicks] DEFAULT ((0)), [DataLossInterval] [float] NOT NULL CONSTRAINT [DF_Device_DataLossInterval] DEFAULT ((5)), [AllowedParsingExceptions] [int] NOT NULL CONSTRAINT [DF_Device_AllowedParsingExceptions] DEFAULT ((10)), [ParsingExceptionWindow] [float] NOT NULL CONSTRAINT [DF_Device_ParsingExceptionWindow] DEFAULT ((5)), [DelayedConnectionInterval] [float] NOT NULL CONSTRAINT [DF_Device_DelayedConnectionInterval] DEFAULT ((5)), [AllowUseOfCachedConfiguration] [bit] NOT NULL CONSTRAINT [DF_Device_AllowUseOfCachedConfiguration] DEFAULT ((1)), [AutoStartDataParsingSequence] [bit] NOT NULL CONSTRAINT [DF_Device_AutoStartDataParsingSequence] DEFAULT ((1)), [SkipDisableRealTimeData] [bit] NOT NULL CONSTRAINT [DF_Device_SkipDisableRealTimeData] DEFAULT ((0)), [MeasurementReportingInterval] [int] NOT NULL CONSTRAINT [DF_Device_MeasurementReportingInterval] DEFAULT ((100000)), [ConnectOnDemand] [bit] NOT NULL CONSTRAINT [DF_Device_ConnectOnDemand] DEFAULT((1)), [ContactList] [nvarchar](max) NULL, [MeasuredLines] [int] NULL, [LoadOrder] [int] NOT NULL CONSTRAINT [DF_Device_LoadOrder] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_Device_Enabled] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_Device_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](50) NOT NULL CONSTRAINT [DF_Device_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_Device_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](50) NOT NULL CONSTRAINT [DF_Device_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [UK_UniqueID] UNIQUE(UniqueID), CONSTRAINT [PK_Device] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO CREATE UNIQUE NONCLUSTERED INDEX [IX_Device_Acronym] ON [dbo].[Device] ( [NodeID] ASC, [Acronym] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO /* This trigger after INSERT and DELETE on [dbo].[Device_RuntimeSync] performs INSERT and DELETE on [dbo].[Runtime] table. */ CREATE TRIGGER [dbo].[Device_RuntimeSync] ON [dbo].[Device] AFTER INSERT, DELETE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; -- If a new record has been added IF EXISTS(SELECT * FROM INSERTED) BEGIN INSERT INTO Runtime (SourceID, SourceTable) SELECT ID, 'Device' FROM INSERTED END -- If a record has been deleted IF EXISTS(SELECT * FROM DELETED) BEGIN DELETE FROM Runtime WHERE SourceID IN (SELECT ID FROM DELETED) AND SourceTable = 'Device' END END GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[VendorDevice]( [ID] [int] IDENTITY(1,1) NOT NULL, [VendorID] [int] NOT NULL CONSTRAINT [DF_VendorDevice_VendorID] DEFAULT ((10)), [Name] [varchar](200) NOT NULL, [Description] [varchar](max) NULL, [URL] [varchar](max) NULL, [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_VendorDevice_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_VendorDevice_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_VendorDevice_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_VendorDevice_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_VendorDevice] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[OutputStreamDeviceDigital]( [NodeID] [uniqueidentifier] NOT NULL, [OutputStreamDeviceID] [int] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [Label] [varchar](max) NOT NULL, [MaskValue] [int] NOT NULL CONSTRAINT [DF_OutputStreamDeviceDigital_MaskValue] DEFAULT ((0)), [LoadOrder] [int] NOT NULL CONSTRAINT [DF_OutputStreamDeviceDigital_LoadOrder] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_OutputStreamDeviceDigital_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OutputStreamDeviceDigital_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_OutputStreamDeviceDigital_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OutputStreamDeviceDigital_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_OutputStreamDeviceDigital] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[OutputStreamDevicePhasor]( [NodeID] [uniqueidentifier] NOT NULL, [OutputStreamDeviceID] [int] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [Label] [varchar](200) NOT NULL, [Type] [nchar](1) NOT NULL CONSTRAINT [DF_OutputStreamDevicePhasor_Type] DEFAULT (N'V'), [Phase] [nchar](1) NOT NULL CONSTRAINT [DF_OutputStreamDevicePhasor_Phase] DEFAULT (N'+'), [ScalingValue] [int] NOT NULL CONSTRAINT [DF_OutputStreamDevicePhasor_ScalingValue] DEFAULT ((0)), [LoadOrder] [int] NOT NULL CONSTRAINT [DF_OutputStreamDevicePhasor_LoadOrder] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_OutputStreamDevicePhasor_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OutputStreamDevicePhasor_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_OutputStreamDevicePhasor_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OutputStreamDevicePhasor_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_OutputStreamDevicePhasor] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[OutputStreamDeviceAnalog]( [NodeID] [uniqueidentifier] NOT NULL, [OutputStreamDeviceID] [int] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [Label] [varchar](200) NOT NULL, [Type] [int] NOT NULL CONSTRAINT [DF_OutputStreamDeviceAnalog_Type] DEFAULT ((0)), [ScalingValue] [int] NOT NULL CONSTRAINT [DF_OutputStreamDeviceAnalog_ScalingValue] DEFAULT ((0)), [LoadOrder] [int] NOT NULL CONSTRAINT [DF_OutputStreamDeviceAnalog_LoadOrder] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_OutputStreamDeviceAnalog_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OutputStreamDeviceAnalog_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_OutputStreamDeviceAnalog_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OutputStreamDeviceAnalog_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_OutputStreamDeviceAnalog] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[Measurement]( [PointID] [bigint] IDENTITY(1,1) NOT NULL, [SignalID] [uniqueidentifier] NOT NULL CONSTRAINT [DF_Measurement_SignalID] DEFAULT (newid()), [HistorianID] [int] NULL, [DeviceID] [int] NULL, [PointTag] [varchar](200) NOT NULL, [AlternateTag] [varchar](max) NULL, [SignalTypeID] [int] NOT NULL, [PhasorSourceIndex] [int] NULL, [SignalReference] [varchar](200) NOT NULL, [Adder] [float] NOT NULL CONSTRAINT [DF_Measurement_Adder] DEFAULT ((0.0)), [Multiplier] [float] NOT NULL CONSTRAINT [DF_Measurement_Multiplier] DEFAULT ((1.0)), [Description] [varchar](max) NULL, [Internal] [bit] NOT NULL CONSTRAINT [DF_Measurement_Internal] DEFAULT ((1)), [Subscribed] [bit] NOT NULL CONSTRAINT [DF_Measurement_Subscribed] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_Measurement_Enabled] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_Measurement_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Measurement_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_Measurement_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Measurement_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_Measurement] PRIMARY KEY CLUSTERED ( [SignalID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO CREATE UNIQUE NONCLUSTERED INDEX [IX_Measurement_PointID] ON [dbo].[Measurement] ( [PointID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[ImportedMeasurement]( [NodeID] [uniqueidentifier] NULL, [SourceNodeID] [uniqueidentifier] NULL, [SignalID] [uniqueidentifier] NULL, [Source] [varchar](200) NOT NULL, [PointID] [bigint] NOT NULL, [PointTag] [varchar](200) NOT NULL, [AlternateTag] [varchar](200) NULL, [SignalTypeAcronym] [varchar](4) NULL, [SignalReference] [varchar](200) NOT NULL, [FramesPerSecond] [int] NULL, [ProtocolAcronym] [varchar](200) NULL, [ProtocolType] [varchar](200) NOT NULL CONSTRAINT [DF_ImportedMeasurement_ProtocolType] DEFAULT ('Frame'), [PhasorID] [int] NULL, [PhasorType] [nchar](1) NULL, [Phase] [nchar](1) NULL, [Adder] [float] NOT NULL CONSTRAINT [DF_ImportedMeasurement_Adder] DEFAULT ((0.0)), [Multiplier] [float] NOT NULL CONSTRAINT [DF_ImportedMeasurement_Multiplier] DEFAULT ((1.0)), [CompanyAcronym] [varchar](200) NULL, [Longitude] [decimal](9,6) NULL, [Latitude] [decimal](9,6) NULL, [Description] [varchar](max) NULL, [Enabled] [bit] NOT NULL CONSTRAINT [DF_ImportedMeasurement_Enabled] DEFAULT ((0)) ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[Statistic]( [ID] [int] IDENTITY(1,1) NOT NULL, [Source] [varchar](20) NOT NULL, [SignalIndex] [int] NOT NULL, [Name] [varchar](200) NOT NULL, [Description] [varchar](max) NULL, [AssemblyName] [varchar](max) NOT NULL, [TypeName] [varchar](max) NOT NULL, [MethodName] [varchar](200) NOT NULL, [Arguments] [varchar](max) NULL, [Enabled] [bit] NOT NULL CONSTRAINT [DF_Statistic_Enabled] DEFAULT ((0)), [DataType] [varchar](200) NULL, [DisplayFormat] [varchar](200) NULL, [IsConnectedState] [bit] NOT NULL CONSTRAINT [DF_Statistic_IsConnectedState] DEFAULT ((0)), [LoadOrder] [int] NOT NULL CONSTRAINT [DF_Statistic_LoadOrder] DEFAULT ((0)), CONSTRAINT [PK_Statistic] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO CREATE UNIQUE NONCLUSTERED INDEX [IX_Statistic_Source_SignalIndex] ON [dbo].[Statistic] ( [Source] ASC, [SignalIndex] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[OutputStreamMeasurement]( [NodeID] [uniqueidentifier] NOT NULL, [AdapterID] [int] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [HistorianID] [int] NULL, [PointID] [bigint] NOT NULL, [SignalReference] [varchar](200) NOT NULL, [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_OutputStreamMeasurement_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OutputStreamMeasurement_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_OutputStreamMeasurement_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OutputStreamMeasurement_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_OutputStreamMeasurement] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[OutputStreamDevice]( [NodeID] [uniqueidentifier] NOT NULL, [AdapterID] [int] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [IDCode] [int] NOT NULL CONSTRAINT [DF_OutputStreamDevices_IDCode] DEFAULT ((0)), [Acronym] [varchar](200) NOT NULL, [BpaAcronym] [varchar](4) NULL, [Name] [varchar](200) NOT NULL, [PhasorDataFormat] [varchar](15) NULL, [FrequencyDataFormat] [varchar](15) NULL, [AnalogDataFormat] [varchar](15) NULL, [CoordinateFormat] [varchar](15) NULL, [LoadOrder] [int] NOT NULL CONSTRAINT [DF_OutputStreamDevices_LoadOrder] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_OutputStreamDevices_Enabled] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_OutputStreamDevice_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OutputStreamDevice_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_OutputStreamDevice_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OutputStreamDevice_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_OutputStreamDevice] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[Phasor]( [ID] [int] IDENTITY(1,1) NOT NULL, [DeviceID] [int] NOT NULL, [Label] [varchar](200) NOT NULL, [Type] [nchar](1) NOT NULL CONSTRAINT [DF_Phasor_Type] DEFAULT (N'V'), [Phase] [nchar](1) NOT NULL CONSTRAINT [DF_Phasor_Phase] DEFAULT (N'+'), [DestinationPhasorID] [int] NULL, [SourceIndex] [int] NOT NULL CONSTRAINT [DF_Phasor_SourceIndex] DEFAULT ((0)), [BaseKV] [int] NOT NULL CONSTRAINT [DF_Phasor_BaseKV] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_Phasor_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Phasor_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_Phasor_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Phasor_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_Phasor] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO CREATE UNIQUE NONCLUSTERED INDEX [IX_Phasor_DeviceID_SourceIndex] ON [dbo].[Phasor] ( [DeviceID] ASC, [SourceIndex] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[CalculatedMeasurement]( [NodeID] [uniqueidentifier] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [Acronym] [varchar](200) NOT NULL, [Name] [varchar](200) NULL, [AssemblyName] [varchar](max) NOT NULL, [TypeName] [varchar](max) NOT NULL, [ConnectionString] [varchar](max) NULL, [ConfigSection] [varchar](200) NULL, [InputMeasurements] [varchar](max) NULL, [OutputMeasurements] [varchar](max) NULL, [MinimumMeasurementsToUse] [int] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_MinimumMeasurementsToUse] DEFAULT ((-1)), [FramesPerSecond] [int] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_FramesPerSecond] DEFAULT ((30)), [LagTime] [float] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_LagTime] DEFAULT ((3.0)), [LeadTime] [float] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_LeadTime] DEFAULT ((1.0)), [UseLocalClockAsRealTime] [bit] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_UseLocalClockAsRealTime] DEFAULT ((0)), [AllowSortsByArrival] [bit] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_AllowSortsByArrival] DEFAULT ((1)), [IgnoreBadTimeStamps] [bit] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_IgnoreBadTimeStamps] DEFAULT ((0)), [TimeResolution] [int] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_TimeResolution] DEFAULT ((10000)), [AllowPreemptivePublishing] [bit] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_AllowPreemptivePublishing] DEFAULT ((1)), [PerformTimeReasonabilityCheck] [bit] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_PerformTimestampReasonabilityCheck] DEFAULT ((1)), [DownsamplingMethod] [varchar](15) NOT NULL CONSTRAINT [DF_CalculatedMeasurement_DownsamplingMethod] DEFAULT (N'LastReceived'), [LoadOrder] [int] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_LoadOrder] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_Enabled] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_CalculatedMeasurement_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_CalculatedMeasurement_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_CalculatedMeasurement_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_CalculatedMeasurement] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TRIGGER [dbo].[CalculatedMeasurement_RuntimeSync] ON [dbo].[CalculatedMeasurement] AFTER INSERT, DELETE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; -- If a new record has been added IF EXISTS(SELECT * FROM INSERTED) BEGIN INSERT INTO Runtime (SourceID, SourceTable) SELECT ID, 'CalculatedMeasurement' FROM INSERTED END -- If a record has been deleted IF EXISTS(SELECT * FROM DELETED) BEGIN DELETE FROM Runtime WHERE SourceID IN (SELECT ID FROM DELETED) AND SourceTable = 'CalculatedMeasurement' END END GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[CustomActionAdapter]( [NodeID] [uniqueidentifier] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [AdapterName] [varchar](200) NOT NULL, [AssemblyName] [varchar](max) NOT NULL, [TypeName] [varchar](max) NOT NULL, [ConnectionString] [varchar](max) NULL, [LoadOrder] [int] NOT NULL CONSTRAINT [DF_CustomActionAdapter_LoadOrder] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_CustomActionAdapter_Enabled] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_CustomActionAdapter_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_CustomActionAdapter_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_CustomActionAdapter_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_CustomActionAdapter_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_CustomActionAdapter] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TRIGGER [dbo].[CustomActionAdapter_RuntimeSync] ON [dbo].[CustomActionAdapter] AFTER INSERT, DELETE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; -- If a new record has been added IF EXISTS(SELECT * FROM INSERTED) BEGIN INSERT INTO Runtime (SourceID, SourceTable) SELECT ID, 'CustomActionAdapter' FROM INSERTED END -- If a record has been deleted IF EXISTS(SELECT * FROM DELETED) BEGIN DELETE FROM Runtime WHERE SourceID IN (SELECT ID FROM DELETED) AND SourceTable = 'CustomActionAdapter' END END GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[Historian]( [NodeID] [uniqueidentifier] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [Acronym] [varchar](200) NOT NULL, [Name] [varchar](200) NULL, [AssemblyName] [varchar](max) NULL, [TypeName] [varchar](max) NULL, [ConnectionString] [varchar](max) NULL, [IsLocal] [bit] NOT NULL CONSTRAINT [DF_Historian_IsLocal] DEFAULT ((1)), [MeasurementReportingInterval] [int] NOT NULL CONSTRAINT [DF_Historian_MeasurementReportingInterval] DEFAULT ((100000)), [Description] [varchar](max) NULL, [LoadOrder] [int] NOT NULL CONSTRAINT [DF_Historian_LoadOrder] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_Historian_Enabled] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_Historian_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Historian_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_Historian_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Historian_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_Historian] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TRIGGER [dbo].[Historian_RuntimeSync] ON [dbo].[Historian] AFTER INSERT, DELETE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; -- If a new record has been added IF EXISTS(SELECT * FROM INSERTED) BEGIN INSERT INTO Runtime (SourceID, SourceTable) SELECT ID, 'Historian' FROM INSERTED END -- If a record has been deleted IF EXISTS(SELECT * FROM DELETED) BEGIN DELETE FROM Runtime WHERE SourceID IN (SELECT ID FROM DELETED) AND SourceTable = 'Historian' END END GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[CustomInputAdapter]( [NodeID] [uniqueidentifier] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [AdapterName] [varchar](200) NOT NULL, [AssemblyName] [varchar](max) NOT NULL, [TypeName] [varchar](max) NOT NULL, [ConnectionString] [varchar](max) NULL, [LoadOrder] [int] NOT NULL CONSTRAINT [DF_CustomInputAdapter_LoadOrder] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_CustomInputAdapter_Enabled] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_CustomInputAdapter_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_CustomInputAdapter_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_CustomInputAdapter_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_CustomInputAdapter_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_CustomInputAdapter] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TRIGGER [dbo].[CustomInputAdapter_RuntimeSync] ON [dbo].[CustomInputAdapter] AFTER INSERT, DELETE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; -- If a new record has been added IF EXISTS(SELECT * FROM INSERTED) BEGIN INSERT INTO Runtime (SourceID, SourceTable) SELECT ID, 'CustomInputAdapter' FROM INSERTED END -- If a record has been deleted IF EXISTS(SELECT * FROM DELETED) BEGIN DELETE FROM Runtime WHERE SourceID IN (SELECT ID FROM DELETED) AND SourceTable = 'CustomInputAdapter' END END GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[CustomFilterAdapter]( [NodeID] [uniqueidentifier] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [AdapterName] [varchar](200) NOT NULL, [AssemblyName] [varchar](max) NOT NULL, [TypeName] [varchar](max) NOT NULL, [ConnectionString] [varchar](max) NULL, [LoadOrder] [int] NOT NULL CONSTRAINT [DF_CustomFilterAdapter_LoadOrder] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_CustomFilterAdapter_Enabled] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_CustomFilterAdapter_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_CustomFilterAdapter_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_CustomFilterAdapter_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_CustomFilterAdapter_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_CustomFilterAdapter] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TRIGGER [dbo].[CustomFilterAdapter_RuntimeSync] ON [dbo].[CustomFilterAdapter] AFTER INSERT, DELETE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; -- If a new record has been added IF EXISTS(SELECT * FROM INSERTED) BEGIN INSERT INTO Runtime (SourceID, SourceTable) SELECT ID, 'CustomFilterAdapter' FROM INSERTED END -- If a record has been deleted IF EXISTS(SELECT * FROM DELETED) BEGIN DELETE FROM Runtime WHERE SourceID IN (SELECT ID FROM DELETED) AND SourceTable = 'CustomFilterAdapter' END END GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[OutputStream]( [NodeID] [uniqueidentifier] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [Acronym] [varchar](200) NOT NULL, [Name] [varchar](200) NULL, [Type] [int] NOT NULL CONSTRAINT [DF_OutputStream_Type] DEFAULT ((0)), [ConnectionString] [varchar](max) NULL, [DataChannel] [varchar](max) NULL, [CommandChannel] [varchar](max) NULL, [IDCode] [int] NOT NULL CONSTRAINT [DF_OutputStream_IDCode] DEFAULT ((0)), [AutoPublishConfigFrame] [bit] NOT NULL CONSTRAINT [DF_OutputStream_AutoPublishConfigFrame] DEFAULT ((0)), [AutoStartDataChannel] [bit] NOT NULL CONSTRAINT [DF_OutputStream_AutoStartDataChannel] DEFAULT ((1)), [NominalFrequency] [int] NOT NULL CONSTRAINT [DF_OutputStream_NominalFrequency] DEFAULT ((60)), [FramesPerSecond] [int] NOT NULL CONSTRAINT [DF_OutputStream_FramesPerSecond] DEFAULT ((30)), [LagTime] [float] NOT NULL CONSTRAINT [DF_OutputStream_LagTime] DEFAULT ((3.0)), [LeadTime] [float] NOT NULL CONSTRAINT [DF_OutputStream_LeadTime] DEFAULT ((1.0)), [UseLocalClockAsRealTime] [bit] NOT NULL CONSTRAINT [DF_OutputStream_UseLocalClockAsRealTime] DEFAULT ((0)), [AllowSortsByArrival] [bit] NOT NULL CONSTRAINT [DF_OutputStream_AllowSortsByArrival] DEFAULT ((1)), [IgnoreBadTimeStamps] [bit] NOT NULL CONSTRAINT [DF_OutputStream_IgnoreBadTimeStamps] DEFAULT ((0)), [TimeResolution] [int] NOT NULL CONSTRAINT [DF_OutputStream_TimeResolution] DEFAULT ((330000)), [AllowPreemptivePublishing] [bit] NOT NULL CONSTRAINT [DF_OutputStream_AllowPreemptivePublishing] DEFAULT ((1)), [PerformTimeReasonabilityCheck] [bit] NOT NULL CONSTRAINT [DF_OutputStream_PerformTimestampReasonabilityCheck] DEFAULT ((1)), [DownsamplingMethod] [varchar](15) NOT NULL CONSTRAINT [DF_OutputStream_DownsamplingMethod] DEFAULT (N'LastReceived'), [DataFormat] [varchar](15) NOT NULL CONSTRAINT [DF_OutputStream_DataFormat] DEFAULT (N'FloatingPoint'), [CoordinateFormat] [varchar](15) NOT NULL CONSTRAINT [DF_OutputStream_CoordinateFormat] DEFAULT (N'Polar'), [CurrentScalingValue] [int] NOT NULL CONSTRAINT [DF_OutputStream_CurrentScalingValue] DEFAULT ((2423)), [VoltageScalingValue] [int] NOT NULL CONSTRAINT [DF_OutputStream_VoltageScalingValue] DEFAULT ((2725785)), [AnalogScalingValue] [int] NOT NULL CONSTRAINT [DF_OutputStream_AnalogScalingValue] DEFAULT ((1373291)), [DigitalMaskValue] [int] NOT NULL CONSTRAINT [DF_OutputStream_DigitMaskValue] DEFAULT ((-65536)), [LoadOrder] [int] NOT NULL CONSTRAINT [DF_OutputStream_LoadOrder] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_OutputStream_Enabled] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_OutputStream_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OutputStream_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_OutputStream_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_OutputStream_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_OutputStream] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO CREATE UNIQUE NONCLUSTERED INDEX [IX_OutputStream_Acronym] ON [dbo].[OutputStream] ( [NodeID] ASC, [Acronym] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TRIGGER [dbo].[OutputStream_RuntimeSync] ON [dbo].[OutputStream] AFTER INSERT, DELETE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; -- If a new record has been added IF EXISTS(SELECT * FROM INSERTED) BEGIN INSERT INTO Runtime (SourceID, SourceTable) SELECT ID, 'OutputStream' FROM INSERTED END -- If a record has been deleted IF EXISTS(SELECT * FROM DELETED) BEGIN DELETE FROM Runtime WHERE SourceID IN (SELECT ID FROM DELETED) AND SourceTable = 'OutputStream' END END GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO SET ANSI_PADDING OFF GO CREATE TABLE [dbo].[PowerCalculation]( [NodeID] [uniqueidentifier] NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [CircuitDescription] [varchar](max) NULL, [VoltageAngleSignalID] [uniqueidentifier] NOT NULL, [VoltageMagSignalID] [uniqueidentifier] NOT NULL, [CurrentAngleSignalID] [uniqueidentifier] NOT NULL, [CurrentMagSignalID] [uniqueidentifier] NOT NULL, [ActivePowerOutputSignalID] [uniqueidentifier] NULL, [ReactivePowerOutputSignalID] [uniqueidentifier] NULL, [ApparentPowerOutputSignalID] [uniqueidentifier] NULL, [Enabled] [bit] NOT NULL, CONSTRAINT [PK_PowerCalculation] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_PADDING OFF GO ALTER TABLE [dbo].[PowerCalculation] WITH CHECK ADD CONSTRAINT [FK_PowerCalculation_Measurement1] FOREIGN KEY([ApparentPowerOutputSignalID]) REFERENCES [dbo].[Measurement] ([SignalID]) GO ALTER TABLE [dbo].[PowerCalculation] WITH CHECK ADD CONSTRAINT [FK_PowerCalculation_Measurement2] FOREIGN KEY([CurrentAngleSignalID]) REFERENCES [dbo].[Measurement] ([SignalID]) GO ALTER TABLE [dbo].[PowerCalculation] WITH CHECK ADD CONSTRAINT [FK_PowerCalculation_Measurement3] FOREIGN KEY([CurrentMagSignalID]) REFERENCES [dbo].[Measurement] ([SignalID]) GO ALTER TABLE [dbo].[PowerCalculation] WITH CHECK ADD CONSTRAINT [FK_PowerCalculation_Measurement4] FOREIGN KEY([ReactivePowerOutputSignalID]) REFERENCES [dbo].[Measurement] ([SignalID]) GO ALTER TABLE [dbo].[PowerCalculation] WITH CHECK ADD CONSTRAINT [FK_PowerCalculation_Measurement5] FOREIGN KEY([ActivePowerOutputSignalID]) REFERENCES [dbo].[Measurement] ([SignalID]) GO ALTER TABLE [dbo].[PowerCalculation] WITH CHECK ADD CONSTRAINT [FK_PowerCalculation_Measurement6] FOREIGN KEY([VoltageAngleSignalID]) REFERENCES [dbo].[Measurement] ([SignalID]) GO ALTER TABLE [dbo].[PowerCalculation] WITH CHECK ADD CONSTRAINT [FK_PowerCalculation_Measurement7] FOREIGN KEY([VoltageMagSignalID]) REFERENCES [dbo].[Measurement] ([SignalID]) GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[Alarm]( [NodeID] [uniqueidentifier] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [TagName] [varchar](200) NOT NULL, [SignalID] [uniqueidentifier] NOT NULL, [AssociatedMeasurementID] [uniqueidentifier] NULL, [Description] [varchar](max) NULL, [Severity] [int] NOT NULL, [Operation] [int] NOT NULL, [SetPoint] [float] NULL, [Tolerance] [float] NULL, [Delay] [float] NULL, [Hysteresis] [float] NULL, [LoadOrder] [int] NOT NULL CONSTRAINT [DF_Alarm_LoadOrder] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_Alarm_Enabled] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_Alarm_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Alarm_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_Alarm_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Alarm_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_Alarm] PRIMARY KEY NONCLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO CREATE NONCLUSTERED INDEX [IX_Alarm_TagName] ON [dbo].[Alarm] ( [TagName] ASC ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[AlarmLog]( [ID] [int] IDENTITY(1,1) NOT NULL, [SignalID] [uniqueidentifier] NOT NULL, [PreviousState] [int] NULL, [NewState] [int] NULL, [Ticks] [bigint] NOT NULL, [Timestamp] [DATETIME2] NOT NULL, [Value] [FLOAT] NOT NULL, CONSTRAINT [PK_AlarmLog] PRIMARY KEY NONCLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_PADDING OFF GO CREATE NONCLUSTERED INDEX [IX_AlarmLog_SignalID] ON [dbo].[AlarmLog] ( [SignalID] ASC ) ON [PRIMARY] GO CREATE NONCLUSTERED INDEX [IX_AlarmLog_PreviousState] ON [dbo].[AlarmLog] ( [PreviousState] ASC ) ON [PRIMARY] GO CREATE NONCLUSTERED INDEX [IX_AlarmLog_NewState] ON [dbo].[AlarmLog] ( [NewState] ASC ) ON [PRIMARY] GO CREATE NONCLUSTERED INDEX [IX_AlarmLog_Timestamp] ON [dbo].[AlarmLog] ( [Timestamp] ASC ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[CustomOutputAdapter]( [NodeID] [uniqueidentifier] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [AdapterName] [varchar](200) NOT NULL, [AssemblyName] [varchar](max) NOT NULL, [TypeName] [varchar](max) NOT NULL, [ConnectionString] [varchar](max) NULL, [LoadOrder] [int] NOT NULL CONSTRAINT [DF_CustomOutputAdapter_LoadOrder] DEFAULT ((0)), [Enabled] [bit] NOT NULL CONSTRAINT [DF_CustomOutputAdapter_Enabled] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_CustomOutputAdapter_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_CustomOutputAdapter_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_CustomOutputAdapter_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_CustomOutputAdapter_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_CustomOutputAdapter] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TRIGGER [dbo].[CustomOutputAdapter_RuntimeSync] ON [dbo].[CustomOutputAdapter] AFTER INSERT, DELETE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; -- If a new record has been added IF EXISTS(SELECT * FROM INSERTED) BEGIN INSERT INTO Runtime (SourceID, SourceTable) SELECT ID, 'CustomOutputAdapter' FROM INSERTED END -- If a record has been deleted IF EXISTS(SELECT * FROM DELETED) BEGIN DELETE FROM Runtime WHERE SourceID IN (SELECT ID FROM DELETED) AND SourceTable = 'CustomOutputAdapter' END END GO -- Application Security Related Tables and Views SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO SET ANSI_PADDING ON GO CREATE TABLE [dbo].[UserAccount]( [ID] [uniqueidentifier] NOT NULL CONSTRAINT [DF_UserAccount_ID] DEFAULT (newid()), [Name] [varchar](200) NOT NULL, [Password] [varchar](200) NULL, [FirstName] [varchar](200) NULL, [LastName] [varchar](200) NULL, [DefaultNodeID] [uniqueidentifier] NOT NULL, [Phone] [varchar](200) NULL, [Email] [varchar](200) NULL, [LockedOut] [bit] NOT NULL CONSTRAINT [DF_UserAccount_LockedOut] DEFAULT ((0)), [UseADAuthentication] [bit] NOT NULL CONSTRAINT [DF_UserAccount_UseADAuthentication] DEFAULT ((1)), [ChangePasswordOn] [datetime] NULL CONSTRAINT [DF_UserAccount_ChangePasswordOn] DEFAULT (dateadd(day,(90),getutcdate())), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_UserAccount_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](50) NOT NULL CONSTRAINT [DF_UserAccount_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_UserAccount_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](50) NOT NULL CONSTRAINT [DF_UserAccount_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_UserAccount] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY] ) ON [PRIMARY] GO CREATE UNIQUE NONCLUSTERED INDEX [IX_UserAccount] ON [dbo].[UserAccount] ( [Name] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] GO SET ANSI_PADDING OFF GO ALTER TABLE [dbo].[UserAccount] WITH CHECK ADD CONSTRAINT [FK_UserAccount_Node] FOREIGN KEY([DefaultNodeID]) REFERENCES [dbo].[Node] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[UserAccount] CHECK CONSTRAINT [FK_UserAccount_Node] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO SET ANSI_PADDING ON GO CREATE TABLE [dbo].[ApplicationRole]( [ID] [uniqueidentifier] NOT NULL CONSTRAINT [DF_ApplicationRole_ID] DEFAULT (newid()), [Name] [varchar](200) NOT NULL, [Description] [varchar](max) NULL, [NodeID] [uniqueidentifier] NOT NULL, [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_ApplicationRole_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_ApplicationRole_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_ApplicationRole_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_ApplicationRole_UpdatedBy] DEFAULT (getutcdate()), CONSTRAINT [PK_ApplicationRole] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY] ) ON [PRIMARY] GO CREATE UNIQUE NONCLUSTERED INDEX [IX_ApplicationRole] ON [dbo].[ApplicationRole] ( [NodeID] ASC, [Name] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] GO SET ANSI_PADDING OFF GO ALTER TABLE [dbo].[ApplicationRole] WITH CHECK ADD CONSTRAINT [FK_ApplicationRole_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[ApplicationRole] CHECK CONSTRAINT [FK_ApplicationRole_Node] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO SET ANSI_PADDING ON GO CREATE TABLE [dbo].[SecurityGroup]( [ID] [uniqueidentifier] NOT NULL CONSTRAINT [DF_SecurityGroup_ID] DEFAULT (newid()), [Name] [varchar](200) NOT NULL, [Description] [varchar](max) NULL, [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_SecurityGroup_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_SecurityGroup_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_SecurityGroup_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_SecurityGroup_UpdatedBy] DEFAULT (getutcdate()), CONSTRAINT [PK_SecurityGroup] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY] ) ON [PRIMARY] GO CREATE UNIQUE NONCLUSTERED INDEX [IX_SecurityGroup] ON [dbo].[SecurityGroup] ( [Name] ASC )WITH (IGNORE_DUP_KEY = OFF) ON [PRIMARY] GO SET ANSI_PADDING OFF GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[SecurityGroupUserAccount]( [SecurityGroupID] [uniqueidentifier] NOT NULL, [UserAccountID] [uniqueidentifier] NOT NULL ) ON [PRIMARY] GO ALTER TABLE [dbo].[SecurityGroupUserAccount] WITH CHECK ADD CONSTRAINT [FK_SecurityGroupUserAccount_SecurityGroup] FOREIGN KEY([SecurityGroupID]) REFERENCES [dbo].[SecurityGroup] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[SecurityGroupUserAccount] CHECK CONSTRAINT [FK_SecurityGroupUserAccount_SecurityGroup] GO ALTER TABLE [dbo].[SecurityGroupUserAccount] WITH CHECK ADD CONSTRAINT [FK_SecurityGroupUserAccount_UserAccount] FOREIGN KEY([UserAccountID]) REFERENCES [dbo].[UserAccount] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[SecurityGroupUserAccount] CHECK CONSTRAINT [FK_SecurityGroupUserAccount_UserAccount] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[ApplicationRoleUserAccount]( [ApplicationRoleID] [uniqueidentifier] NOT NULL, [UserAccountID] [uniqueidentifier] NOT NULL ) ON [PRIMARY] GO ALTER TABLE [dbo].[ApplicationRoleUserAccount] WITH CHECK ADD CONSTRAINT [FK_ApplicationRoleUserAccount_ApplicationRole] FOREIGN KEY([ApplicationRoleID]) REFERENCES [dbo].[ApplicationRole] ([ID]) GO ALTER TABLE [dbo].[ApplicationRoleUserAccount] CHECK CONSTRAINT [FK_ApplicationRoleUserAccount_ApplicationRole] GO ALTER TABLE [dbo].[ApplicationRoleUserAccount] WITH CHECK ADD CONSTRAINT [FK_ApplicationRoleUserAccount_UserAccount] FOREIGN KEY([UserAccountID]) REFERENCES [dbo].[UserAccount] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[ApplicationRoleUserAccount] CHECK CONSTRAINT [FK_ApplicationRoleUserAccount_UserAccount] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE TABLE [dbo].[ApplicationRoleSecurityGroup]( [ApplicationRoleID] [uniqueidentifier] NOT NULL, [SecurityGroupID] [uniqueidentifier] NOT NULL ) ON [PRIMARY] GO ALTER TABLE [dbo].[ApplicationRoleSecurityGroup] WITH CHECK ADD CONSTRAINT [FK_ApplicationRoleSecurityGroup_SecurityGroup] FOREIGN KEY([SecurityGroupID]) REFERENCES [dbo].[SecurityGroup] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[ApplicationRoleSecurityGroup] CHECK CONSTRAINT [FK_ApplicationRoleSecurityGroup_SecurityGroup] GO ALTER TABLE [dbo].[ApplicationRoleSecurityGroup] WITH CHECK ADD CONSTRAINT [FK_ApplicationRoleSecurityGroup_ApplicationRole] FOREIGN KEY([ApplicationRoleID]) REFERENCES [dbo].[ApplicationRole] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[ApplicationRoleSecurityGroup] CHECK CONSTRAINT [FK_ApplicationRoleSecurityGroup_ApplicationRole] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO SET ANSI_PADDING ON GO CREATE TABLE [dbo].[AccessLog]( [ID] [int] IDENTITY(1,1) NOT NULL, [UserName] [varchar](200) NOT NULL, [AccessGranted] [bit] NOT NULL, [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_AccessLog_Timestamp] DEFAULT (getutcdate()), CONSTRAINT [PK_AccessLog] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_PADDING OFF GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO SET ANSI_PADDING ON GO CREATE TABLE [dbo].[Subscriber]( [NodeID] [uniqueidentifier] NOT NULL, [ID] [uniqueidentifier] NOT NULL CONSTRAINT [DF_Subscriber_ID] DEFAULT (newid()), [Acronym] [varchar](200) NOT NULL, [Name] [varchar](200) NULL, [SharedSecret] [varchar](200) NULL, [AuthKey] [varchar](max) NULL, [ValidIPAddresses] [varchar](max) NULL, [RemoteCertificateFile] [varchar](500) NULL, [ValidPolicyErrors] [varchar](200) NULL, [ValidChainFlags] [varchar](500) NULL, [AccessControlFilter] [varchar](max) NULL, [Enabled] [bit] NOT NULL CONSTRAINT [DF_Subscriber_Enabled] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_Subscriber_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Subscriber_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_Subscriber_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_Subscriber_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_Subscriber] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_PADDING OFF GO ALTER TABLE [dbo].[Subscriber] WITH CHECK ADD CONSTRAINT [FK_Subscriber_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[Subscriber] CHECK CONSTRAINT [FK_Subscriber_Node] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO SET ANSI_PADDING ON GO CREATE TABLE [dbo].[MeasurementGroup]( [NodeID] [uniqueidentifier] NOT NULL, [ID] [int] IDENTITY(1,1) NOT NULL, [Name] [varchar](200) NOT NULL, [Description] [varchar](max) NULL, [FilterExpression] [varchar](max) NULL, [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_MeasurementGroup_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_MeasurementGroup_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_MeasurementGroup_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_MeasurementGroup_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_MeasurementGroup] PRIMARY KEY CLUSTERED ( [ID] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_PADDING OFF GO ALTER TABLE [dbo].[MeasurementGroup] WITH CHECK ADD CONSTRAINT [FK_MeasurementGroup_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[MeasurementGroup] CHECK CONSTRAINT [FK_MeasurementGroup_Node] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO SET ANSI_PADDING ON GO CREATE TABLE [dbo].[MeasurementGroupMeasurement]( [NodeID] [uniqueidentifier] NOT NULL, [MeasurementGroupID] [int] NOT NULL, [SignalID] [uniqueidentifier] NOT NULL, [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_MeasurementGroupMeasurement_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_MeasurementGroupMeasurement_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_MeasurementGroupMeasurement_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_MeasurementGroupMeasurement_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_MeasurementGroupMeasurement] PRIMARY KEY CLUSTERED ( [NodeID] ASC, [MeasurementGroupID] ASC, [SignalID] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_PADDING OFF GO ALTER TABLE [dbo].[MeasurementGroupMeasurement] WITH CHECK ADD CONSTRAINT [FK_MeasurementGroupMeasurement_Measurement] FOREIGN KEY([SignalID]) REFERENCES [dbo].[Measurement] ([SignalID]) GO ALTER TABLE [dbo].[MeasurementGroupMeasurement] CHECK CONSTRAINT [FK_MeasurementGroupMeasurement_Measurement] GO ALTER TABLE [dbo].[MeasurementGroupMeasurement] WITH CHECK ADD CONSTRAINT [FK_MeasurementGroupMeasurement_MeasurementGroup] FOREIGN KEY([MeasurementGroupID]) REFERENCES [dbo].[MeasurementGroup] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[MeasurementGroupMeasurement] CHECK CONSTRAINT [FK_MeasurementGroupMeasurement_MeasurementGroup] GO ALTER TABLE [dbo].[MeasurementGroupMeasurement] WITH CHECK ADD CONSTRAINT [FK_MeasurementGroupMeasurement_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) GO ALTER TABLE [dbo].[MeasurementGroupMeasurement] CHECK CONSTRAINT [FK_MeasurementGroupMeasurement_Node] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO SET ANSI_PADDING ON GO CREATE TABLE [dbo].[SubscriberMeasurement]( [NodeID] [uniqueidentifier] NOT NULL, [SubscriberID] [uniqueidentifier] NOT NULL, [SignalID] [uniqueidentifier] NOT NULL, [Allowed] [bit] NOT NULL CONSTRAINT [DF_SubscriberMeasurement_Allowed] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_SubscriberMeasurement_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_SubscriberMeasurement_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_SubscriberMeasurement_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_SubscriberMeasurement_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_SubscriberMeasurement] PRIMARY KEY CLUSTERED ( [NodeID] ASC, [SubscriberID] ASC, [SignalID] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_PADDING OFF GO ALTER TABLE [dbo].[SubscriberMeasurement] WITH CHECK ADD CONSTRAINT [FK_SubscriberMeasurement_Measurement] FOREIGN KEY([SignalID]) REFERENCES [dbo].[Measurement] ([SignalID]) GO ALTER TABLE [dbo].[SubscriberMeasurement] CHECK CONSTRAINT [FK_SubscriberMeasurement_Measurement] GO ALTER TABLE [dbo].[SubscriberMeasurement] WITH CHECK ADD CONSTRAINT [FK_SubscriberMeasurement_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) GO ALTER TABLE [dbo].[SubscriberMeasurement] CHECK CONSTRAINT [FK_SubscriberMeasurement_Node] GO ALTER TABLE [dbo].[SubscriberMeasurement] WITH CHECK ADD CONSTRAINT [FK_SubscriberMeasurement_Subscriber] FOREIGN KEY([SubscriberID]) REFERENCES [dbo].[Subscriber] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[SubscriberMeasurement] CHECK CONSTRAINT [FK_SubscriberMeasurement_Subscriber] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO SET ANSI_PADDING ON GO CREATE TABLE [dbo].[SubscriberMeasurementGroup]( [NodeID] [uniqueidentifier] NOT NULL, [SubscriberID] [uniqueidentifier] NOT NULL, [MeasurementGroupID] [int] NOT NULL, [Allowed] [bit] NOT NULL CONSTRAINT [DF_SubscriberMeasurementGroup_Allowed] DEFAULT ((0)), [CreatedOn] [datetime] NOT NULL CONSTRAINT [DF_SubscriberMeasurementGroup_CreatedOn] DEFAULT (getutcdate()), [CreatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_SubscriberMeasurementGroup_CreatedBy] DEFAULT (suser_name()), [UpdatedOn] [datetime] NOT NULL CONSTRAINT [DF_SubscriberMeasurementGroup_UpdatedOn] DEFAULT (getutcdate()), [UpdatedBy] [varchar](200) NOT NULL CONSTRAINT [DF_SubscriberMeasurementGroup_UpdatedBy] DEFAULT (suser_name()), CONSTRAINT [PK_SubscriberMeasurementGroup] PRIMARY KEY CLUSTERED ( [NodeID] ASC, [SubscriberID] ASC, [MeasurementGroupID] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY] ) ON [PRIMARY] GO SET ANSI_PADDING OFF GO ALTER TABLE [dbo].[SubscriberMeasurementGroup] WITH CHECK ADD CONSTRAINT [FK_SubscriberMeasurementGroup_MeasurementGroup] FOREIGN KEY([MeasurementGroupID]) REFERENCES [dbo].[MeasurementGroup] ([ID]) GO ALTER TABLE [dbo].[SubscriberMeasurementGroup] CHECK CONSTRAINT [FK_SubscriberMeasurementGroup_MeasurementGroup] GO ALTER TABLE [dbo].[SubscriberMeasurementGroup] WITH CHECK ADD CONSTRAINT [FK_SubscriberMeasurementGroup_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) GO ALTER TABLE [dbo].[SubscriberMeasurementGroup] CHECK CONSTRAINT [FK_SubscriberMeasurementGroup_Node] GO ALTER TABLE [dbo].[SubscriberMeasurementGroup] WITH CHECK ADD CONSTRAINT [FK_SubscriberMeasurementGroup_Subscriber] FOREIGN KEY([SubscriberID]) REFERENCES [dbo].[Subscriber] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[SubscriberMeasurementGroup] CHECK CONSTRAINT [FK_SubscriberMeasurementGroup_Subscriber] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[NodeInfo] AS SELECT dbo.Node.ID AS NodeID, dbo.Node.Name, dbo.Company.Name AS CompanyName, dbo.Node.Longitude, dbo.Node.Latitude, dbo.Node.Description, dbo.Node.ImagePath, dbo.Node.Settings, dbo.Node.MenuType, dbo.Node.MenuData, dbo.Node.Master, dbo.Node.Enabled FROM dbo.Node WITH (NOLOCK) LEFT OUTER JOIN dbo.Company WITH (NOLOCK) ON dbo.Node.CompanyID = dbo.Company.ID GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[SecurityGroupUserAccountDetail] AS SELECT dbo.SecurityGroupUserAccount.SecurityGroupID, dbo.SecurityGroupUserAccount.UserAccountID, UserAccount.Name AS UserName, UserAccount.FirstName, UserAccount.LastName, UserAccount.Email, dbo.SecurityGroup.Name AS SecurityGroupName, dbo.SecurityGroup.Description AS SecurityGroupDescription FROM dbo.SecurityGroupUserAccount WITH (NOLOCK) INNER JOIN dbo.SecurityGroup WITH (NOLOCK) ON dbo.SecurityGroupUserAccount.SecurityGroupID = dbo.SecurityGroup.ID INNER JOIN UserAccount WITH (NOLOCK) ON dbo.SecurityGroupUserAccount.UserAccountID = UserAccount.ID GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[AppRoleSecurityGroupDetail] AS SELECT ApplicationRoleSecurityGroup.ApplicationRoleID, ApplicationRoleSecurityGroup.SecurityGroupID, ApplicationRole.Name AS ApplicationRoleName, ApplicationRole.Description AS ApplicationRoleDescription, SecurityGroup.Name AS SecurityGroupName, SecurityGroup.Description AS SecurityGroupDescription FROM ApplicationRoleSecurityGroup WITH (NOLOCK), ApplicationRole WITH (NOLOCK), SecurityGroup WITH (NOLOCK) WHERE ApplicationRoleSecurityGroup.ApplicationRoleID = ApplicationRole.ID AND ApplicationRoleSecurityGroup.SecurityGroupID = SecurityGroup.ID GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[AppRoleUserAccountDetail] AS SELECT dbo.ApplicationRoleUserAccount.ApplicationRoleID, dbo.ApplicationRoleUserAccount.UserAccountID, UserAccount.Name AS UserName, UserAccount.FirstName, UserAccount.LastName, UserAccount.Email, dbo.ApplicationRole.Name AS ApplicationRoleName, dbo.ApplicationRole.Description AS ApplicationRoleDescription FROM dbo.ApplicationRoleUserAccount WITH (NOLOCK) INNER JOIN dbo.ApplicationRole WITH (NOLOCK) ON dbo.ApplicationRoleUserAccount.ApplicationRoleID = dbo.ApplicationRole.ID INNER JOIN UserAccount WITH (NOLOCK) ON dbo.ApplicationRoleUserAccount.UserAccountID = UserAccount.ID GO -- End of Application Security related tables and views definitions. SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[RuntimeOutputStreamMeasurement] AS SELECT TOP (100) PERCENT dbo.OutputStreamMeasurement.NodeID, dbo.Runtime.ID AS AdapterID, dbo.Historian.Acronym AS Historian, dbo.OutputStreamMeasurement.PointID, dbo.OutputStreamMeasurement.SignalReference FROM dbo.OutputStreamMeasurement WITH (NOLOCK) LEFT OUTER JOIN dbo.Historian WITH (NOLOCK) ON dbo.OutputStreamMeasurement.HistorianID = dbo.Historian.ID LEFT OUTER JOIN dbo.Runtime WITH (NOLOCK) ON dbo.OutputStreamMeasurement.AdapterID = dbo.Runtime.SourceID AND dbo.Runtime.SourceTable = N'OutputStream' ORDER BY dbo.OutputStreamMeasurement.HistorianID, dbo.OutputStreamMeasurement.PointID GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[RuntimeHistorian] AS SELECT TOP (100) PERCENT dbo.Historian.NodeID, dbo.Runtime.ID, dbo.Historian.Acronym AS AdapterName, COALESCE (NULLIF(LTRIM(RTRIM(dbo.Historian.AssemblyName)), ''), N'HistorianAdapters.dll') AS AssemblyName, COALESCE (NULLIF(LTRIM(RTRIM(dbo.Historian.TypeName)), ''), CASE dbo.Historian.IsLocal WHEN 1 THEN N'HistorianAdapters.LocalOutputAdapter' ELSE N'HistorianAdapters.RemoteOutputAdapter' END) AS TypeName, CASE WHEN Historian.ConnectionString IS NULL THEN N'' ELSE Historian.ConnectionString + N'; ' END + N'instanceName=' + dbo.Historian.Acronym + N'; sourceids=' + dbo.Historian.Acronym + N'; measurementReportingInterval=' + CONVERT(NVARCHAR(10), dbo.Historian.MeasurementReportingInterval) AS ConnectionString FROM dbo.Historian WITH (NOLOCK) LEFT OUTER JOIN dbo.Runtime WITH (NOLOCK) ON dbo.Historian.ID = dbo.Runtime.SourceID AND dbo.Runtime.SourceTable = N'Historian' WHERE (dbo.Historian.Enabled <> 0) ORDER BY dbo.Historian.LoadOrder GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[RuntimeDevice] AS SELECT TOP (100) PERCENT dbo.Device.NodeID, dbo.Runtime.ID, dbo.Device.Acronym AS AdapterName, dbo.Protocol.AssemblyName, dbo.Protocol.TypeName, CASE WHEN dbo.Device.ConnectionString IS NULL THEN N'' ELSE dbo.Device.ConnectionString END + N'; isConcentrator=' + CONVERT(NVARCHAR(10), dbo.Device.IsConcentrator) + N'; accessID=' + CONVERT(NVARCHAR(10), dbo.Device.AccessID) + CASE WHEN dbo.Device.TimeZone IS NULL THEN N'' ELSE N'; timeZone=' + dbo.Device.TimeZone END + N'; timeAdjustmentTicks=' + CONVERT(NVARCHAR(30), dbo.Device.TimeAdjustmentTicks) + CASE WHEN dbo.Protocol.Acronym IS NULL THEN N'' ELSE N'; phasorProtocol=' + dbo.Protocol.Acronym END + N'; dataLossInterval=' + CONVERT(NVARCHAR(10), dbo.Device.DataLossInterval) + N'; allowedParsingExceptions=' + CONVERT(NVARCHAR(10), dbo.Device.AllowedParsingExceptions) + N'; parsingExceptionWindow=' + CONVERT(NVARCHAR(10), dbo.Device.ParsingExceptionWindow) + N'; delayedConnectionInterval=' + CONVERT(NVARCHAR(10), dbo.Device.DelayedConnectionInterval) + N'; allowUseOfCachedConfiguration=' + CONVERT (NVARCHAR(10), dbo.Device.AllowUseOfCachedConfiguration) + N'; autoStartDataParsingSequence=' + CONVERT(NVARCHAR(10), dbo.Device.AutoStartDataParsingSequence) + N'; skipDisableRealTimeData=' + CONVERT(NVARCHAR(10), dbo.Device.SkipDisableRealTimeData) + N'; measurementReportingInterval=' + CONVERT(NVARCHAR(10), dbo.Device.MeasurementReportingInterval) + N'; connectOnDemand=' + CONVERT(NVARCHAR(10), dbo.Device.ConnectOnDemand) AS ConnectionString FROM dbo.Device WITH (NOLOCK) LEFT OUTER JOIN dbo.Protocol WITH (NOLOCK) ON dbo.Device.ProtocolID = dbo.Protocol.ID LEFT OUTER JOIN dbo.Runtime WITH (NOLOCK) ON dbo.Device.ID = dbo.Runtime.SourceID AND dbo.Runtime.SourceTable = N'Device' WHERE (dbo.Device.Enabled <> 0 AND Device.ParentID IS NULL) ORDER BY dbo.Device.LoadOrder GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[RuntimeCustomOutputAdapter] AS SELECT TOP (100) PERCENT dbo.CustomOutputAdapter.NodeID, dbo.Runtime.ID, dbo.CustomOutputAdapter.AdapterName, LTRIM(RTRIM(dbo.CustomOutputAdapter.AssemblyName)) AS AssemblyName, LTRIM(RTRIM(dbo.CustomOutputAdapter.TypeName)) AS TypeName, dbo.CustomOutputAdapter.ConnectionString FROM dbo.CustomOutputAdapter WITH (NOLOCK) LEFT OUTER JOIN dbo.Runtime WITH (NOLOCK) ON dbo.CustomOutputAdapter.ID = dbo.Runtime.SourceID AND dbo.Runtime.SourceTable = N'CustomOutputAdapter' WHERE (dbo.CustomOutputAdapter.Enabled <> 0) ORDER BY dbo.CustomOutputAdapter.LoadOrder GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[RuntimeInputStreamDevice] AS SELECT TOP (100) PERCENT dbo.Device.NodeID, Runtime_P.ID AS ParentID, dbo.Runtime.ID, dbo.Device.Acronym, dbo.Device.Name, dbo.Device.AccessID FROM dbo.Device WITH (NOLOCK) LEFT OUTER JOIN dbo.Runtime WITH (NOLOCK) ON dbo.Device.ID = dbo.Runtime.SourceID AND dbo.Runtime.SourceTable = N'Device' LEFT OUTER JOIN dbo.Runtime AS Runtime_P WITH (NOLOCK) ON dbo.Device.ParentID = Runtime_P.SourceID AND Runtime_P.SourceTable = N'Device' WHERE (dbo.Device.IsConcentrator = 0) AND (dbo.Device.Enabled <> 0) AND (dbo.Device.ParentID IS NOT NULL) ORDER BY dbo.Device.LoadOrder GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[RuntimeCustomInputAdapter] AS SELECT TOP (100) PERCENT dbo.CustomInputAdapter.NodeID, dbo.Runtime.ID, dbo.CustomInputAdapter.AdapterName, LTRIM(RTRIM(dbo.CustomInputAdapter.AssemblyName)) AS AssemblyName, LTRIM(RTRIM(dbo.CustomInputAdapter.TypeName)) AS TypeName, dbo.CustomInputAdapter.ConnectionString FROM dbo.CustomInputAdapter WITH (NOLOCK) LEFT OUTER JOIN dbo.Runtime WITH (NOLOCK) ON dbo.CustomInputAdapter.ID = dbo.Runtime.SourceID AND dbo.Runtime.SourceTable = N'CustomInputAdapter' WHERE (dbo.CustomInputAdapter.Enabled <> 0) ORDER BY dbo.CustomInputAdapter.LoadOrder GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[RuntimeCustomFilterAdapter] AS SELECT TOP (100) PERCENT dbo.CustomFilterAdapter.NodeID, dbo.Runtime.ID, dbo.CustomFilterAdapter.AdapterName, LTRIM(RTRIM(dbo.CustomFilterAdapter.AssemblyName)) AS AssemblyName, LTRIM(RTRIM(dbo.CustomFilterAdapter.TypeName)) AS TypeName, dbo.CustomFilterAdapter.ConnectionString FROM dbo.CustomFilterAdapter WITH (NOLOCK) LEFT OUTER JOIN dbo.Runtime WITH (NOLOCK) ON dbo.CustomFilterAdapter.ID = dbo.Runtime.SourceID AND dbo.Runtime.SourceTable = N'CustomFilterAdapter' WHERE (dbo.CustomFilterAdapter.Enabled <> 0) ORDER BY dbo.CustomFilterAdapter.LoadOrder GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[RuntimeOutputStreamDevice] AS SELECT TOP (100) PERCENT dbo.OutputStreamDevice.NodeID, dbo.Runtime.ID AS ParentID, dbo.OutputStreamDevice.ID, dbo.OutputStreamDevice.IDCode, dbo.OutputStreamDevice.Acronym, dbo.OutputStreamDevice.BpaAcronym, dbo.OutputStreamDevice.Name, NULLIF(dbo.OutputStreamDevice.PhasorDataFormat, '') AS PhasorDataFormat, NULLIF(dbo.OutputStreamDevice.FrequencyDataFormat, '') AS FrequencyDataFormat, NULLIF(dbo.OutputStreamDevice.AnalogDataFormat, '') AS AnalogDataFormat, NULLIF(dbo.OutputStreamDevice.CoordinateFormat, '') AS CoordinateFormat, dbo.OutputStreamDevice.LoadOrder FROM dbo.OutputStreamDevice WITH (NOLOCK) LEFT OUTER JOIN dbo.Runtime WITH (NOLOCK) ON dbo.OutputStreamDevice.AdapterID = dbo.Runtime.SourceID AND dbo.Runtime.SourceTable = N'OutputStream' WHERE (dbo.OutputStreamDevice.Enabled <> 0) ORDER BY dbo.OutputStreamDevice.LoadOrder GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[RuntimeOutputStream] AS SELECT TOP (100) PERCENT dbo.OutputStream.NodeID, dbo.Runtime.ID, dbo.OutputStream.Acronym AS AdapterName, N'PhasorProtocolAdapters.dll' AS AssemblyName, CASE Type WHEN 1 THEN N'PhasorProtocolAdapters.BpaPdcStream.Concentrator' WHEN 2 THEN N'PhasorProtocolAdapters.Iec61850_90_5.Concentrator' ELSE N'PhasorProtocolAdapters.IeeeC37_118.Concentrator' END AS TypeName, CASE WHEN dbo.OutputStream.ConnectionString IS NULL THEN N'' ELSE dbo.OutputStream.ConnectionString + N'; ' END + CASE WHEN dbo.OutputStream.DataChannel IS NULL THEN N'' ELSE N'dataChannel={' + dbo.OutputStream.DataChannel + N'}' END + CASE WHEN dbo.OutputStream.CommandChannel IS NULL THEN N'' ELSE N'; commandChannel={' + dbo.OutputStream.CommandChannel + N'}' END + N'; idCode=' + CONVERT(NVARCHAR(10), dbo.OutputStream.IDCode) + N'; autoPublishConfigFrame=' + CONVERT(NVARCHAR(10), dbo.OutputStream.AutoPublishConfigFrame) + N'; autoStartDataChannel=' + CONVERT(NVARCHAR(10), dbo.OutputStream.AutoStartDataChannel) + N'; nominalFrequency=' + CONVERT(NVARCHAR(10), dbo.OutputStream.NominalFrequency) + N'; lagTime=' + CONVERT(NVARCHAR(10), dbo.OutputStream.LagTime) + N'; leadTime=' + CONVERT(NVARCHAR(10), dbo.OutputStream.LeadTime) + N'; framesPerSecond=' + CONVERT(NVARCHAR(10), dbo.OutputStream.FramesPerSecond) + N'; useLocalClockAsRealTime=' + CONVERT(NVARCHAR(10), dbo.OutputStream.UseLocalClockAsRealTime) + N'; allowSortsByArrival=' + CONVERT(NVARCHAR(10), dbo.OutputStream.AllowSortsByArrival) + N'; ignoreBadTimestamps=' + CONVERT(NVARCHAR(10), dbo.OutputStream.IgnoreBadTimestamps) + N'; timeResolution=' + CONVERT(NVARCHAR(10), dbo.OutputStream.TimeResolution) + N'; allowPreemptivePublishing=' + CONVERT(NVARCHAR(10), dbo.OutputStream.AllowPreemptivePublishing) + N'; performTimestampReasonabilityCheck=' + CONVERT(NVARCHAR(10), dbo.OutputStream.PerformTimeReasonabilityCheck) + N'; downsamplingMethod=' + dbo.OutputStream.DownsamplingMethod + N'; dataFormat=' + dbo.OutputStream.DataFormat + N'; coordinateFormat=' + dbo.OutputStream.CoordinateFormat + N'; currentScalingValue=' + CONVERT(NVARCHAR(10), dbo.OutputStream.CurrentScalingValue) + N'; voltageScalingValue=' + CONVERT(NVARCHAR(10), dbo.OutputStream.VoltageScalingValue) + N'; analogScalingValue=' + CONVERT(NVARCHAR(10), dbo.OutputStream.AnalogScalingValue) + N'; digitalMaskValue=' + CONVERT(NVARCHAR(10), dbo.OutputStream.DigitalMaskValue) AS ConnectionString FROM dbo.OutputStream WITH (NOLOCK) LEFT OUTER JOIN dbo.Runtime WITH (NOLOCK) ON dbo.OutputStream.ID = dbo.Runtime.SourceID AND dbo.Runtime.SourceTable = N'OutputStream' WHERE (dbo.OutputStream.Enabled <> 0) ORDER BY dbo.OutputStream.LoadOrder GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[RuntimeCustomActionAdapter] AS SELECT TOP (100) PERCENT dbo.CustomActionAdapter.NodeID, dbo.Runtime.ID, dbo.CustomActionAdapter.AdapterName, LTRIM(RTRIM(dbo.CustomActionAdapter.AssemblyName)) AS AssemblyName, LTRIM(RTRIM(dbo.CustomActionAdapter.TypeName)) AS TypeName, dbo.CustomActionAdapter.ConnectionString FROM dbo.CustomActionAdapter WITH (NOLOCK) LEFT OUTER JOIN dbo.Runtime WITH (NOLOCK) ON dbo.CustomActionAdapter.ID = dbo.Runtime.SourceID AND dbo.Runtime.SourceTable = N'CustomActionAdapter' WHERE (dbo.CustomActionAdapter.Enabled <> 0) ORDER BY dbo.CustomActionAdapter.LoadOrder GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[MeasurementDetail] AS SELECT dbo.Device.CompanyID, dbo.Company.Acronym AS CompanyAcronym, dbo.Company.Name AS CompanyName, dbo.Measurement.SignalID, dbo.Measurement.HistorianID, dbo.Historian.Acronym AS HistorianAcronym, dbo.Historian.ConnectionString AS HistorianConnectionString, dbo.Measurement.PointID, dbo.Measurement.PointTag, dbo.Measurement.AlternateTag, dbo.Measurement.DeviceID, COALESCE (dbo.Device.NodeID, dbo.Historian.NodeID) AS NodeID, dbo.Device.Acronym AS DeviceAcronym, dbo.Device.Name AS DeviceName, COALESCE(dbo.Device.FramesPerSecond, 30) AS FramesPerSecond, dbo.Device.Enabled AS DeviceEnabled, dbo.Device.ContactList, dbo.Device.VendorDeviceID, dbo.VendorDevice.Name AS VendorDeviceName, dbo.VendorDevice.Description AS VendorDeviceDescription, dbo.Device.ProtocolID, dbo.Protocol.Acronym AS ProtocolAcronym, dbo.Protocol.Name AS ProtocolName, dbo.Measurement.SignalTypeID, dbo.Measurement.PhasorSourceIndex, dbo.Phasor.Label AS PhasorLabel, dbo.Phasor.Type AS PhasorType, dbo.Phasor.Phase, dbo.Phasor.BaseKV, dbo.Measurement.SignalReference, dbo.Measurement.Adder, dbo.Measurement.Multiplier, dbo.Measurement.Description, dbo.Measurement.Subscribed, dbo.Measurement.Internal, dbo.Measurement.Enabled, COALESCE (dbo.SignalType.EngineeringUnits, N'') AS EngineeringUnits, dbo.SignalType.Source, dbo.SignalType.Acronym AS SignalAcronym, dbo.SignalType.Name AS SignalName, dbo.SignalType.Suffix AS SignalTypeSuffix, dbo.Device.Longitude, dbo.Device.Latitude, COALESCE(Historian.Acronym, Device.Acronym, '__') + ':' + CONVERT(NVARCHAR(10), Measurement.PointID) AS ID, Measurement.UpdatedOn FROM dbo.Company WITH (NOLOCK) RIGHT OUTER JOIN dbo.Device WITH (NOLOCK) ON dbo.Company.ID = dbo.Device.CompanyID RIGHT OUTER JOIN dbo.Measurement WITH (NOLOCK) LEFT OUTER JOIN dbo.SignalType WITH (NOLOCK) ON dbo.Measurement.SignalTypeID = dbo.SignalType.ID ON dbo.Device.ID = dbo.Measurement.DeviceID LEFT OUTER JOIN dbo.Phasor WITH (NOLOCK) ON dbo.Measurement.DeviceID = dbo.Phasor.DeviceID AND dbo.Measurement.PhasorSourceIndex = dbo.Phasor.SourceIndex LEFT OUTER JOIN dbo.VendorDevice WITH (NOLOCK) ON dbo.Device.VendorDeviceID = dbo.VendorDevice.ID LEFT OUTER JOIN dbo.Protocol WITH (NOLOCK) ON dbo.Device.ProtocolID = dbo.Protocol.ID LEFT OUTER JOIN dbo.Historian WITH (NOLOCK) ON dbo.Measurement.HistorianID = dbo.Historian.ID GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[RuntimeCalculatedMeasurement] AS SELECT TOP (100) PERCENT dbo.CalculatedMeasurement.NodeID, dbo.Runtime.ID, dbo.CalculatedMeasurement.Acronym AS AdapterName, LTRIM(RTRIM(dbo.CalculatedMeasurement.AssemblyName)) AS AssemblyName, LTRIM(RTRIM(dbo.CalculatedMeasurement.TypeName)) AS TypeName, CASE WHEN dbo.CalculatedMeasurement.ConnectionString IS NULL THEN N'' ELSE dbo.CalculatedMeasurement.ConnectionString + N'; ' END + CASE WHEN ConfigSection IS NULL THEN N'' ELSE N'configurationSection=' + ConfigSection + N'; ' END + N'minimumMeasurementsToUse=' + CONVERT(NVARCHAR(10), dbo.CalculatedMeasurement.MinimumMeasurementsToUse) + N'; framesPerSecond=' + CONVERT(NVARCHAR(10), dbo.CalculatedMeasurement.FramesPerSecond) + N'; lagTime=' + CONVERT(NVARCHAR(10), dbo.CalculatedMeasurement.LagTime) + N'; leadTime=' + CONVERT(NVARCHAR(10), dbo.CalculatedMeasurement.LeadTime) + CASE WHEN InputMeasurements IS NULL THEN N'' ELSE N'; inputMeasurementKeys={' + InputMeasurements + '}' END + CASE WHEN OutputMeasurements IS NULL THEN N'' ELSE N'; outputMeasurements={' + OutputMeasurements + '}' END + N'; ignoreBadTimestamps=' + CONVERT(NVARCHAR(10), dbo.CalculatedMeasurement.IgnoreBadTimeStamps) + N'; timeResolution=' + CONVERT(NVARCHAR(10), dbo.CalculatedMeasurement.TimeResolution) + N'; allowPreemptivePublishing=' + CONVERT(NVARCHAR(10), dbo.CalculatedMeasurement.AllowPreemptivePublishing) + N'; performTimestampReasonabilityCheck=' + CONVERT(NVARCHAR(10), dbo.CalculatedMeasurement.PerformTimeReasonabilityCheck) + N'; downsamplingMethod=' + dbo.CalculatedMeasurement.DownsamplingMethod + N'; useLocalClockAsRealTime=' + CONVERT(NVARCHAR(10), dbo.CalculatedMeasurement.UseLocalClockAsRealTime) AS ConnectionString FROM dbo.CalculatedMeasurement WITH (NOLOCK) LEFT OUTER JOIN dbo.Runtime WITH (NOLOCK) ON dbo.CalculatedMeasurement.ID = dbo.Runtime.SourceID AND dbo.Runtime.SourceTable = N'CalculatedMeasurement' WHERE (dbo.CalculatedMeasurement.Enabled <> 0) ORDER BY dbo.CalculatedMeasurement.LoadOrder GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[ActiveMeasurement] AS SELECT dbo.Node.ID AS NodeID, COALESCE(dbo.Device.NodeID, dbo.Historian.NodeID) AS SourceNodeID, COALESCE(dbo.Historian.Acronym, dbo.Device.Acronym, '__') + ':' + CONVERT(NVARCHAR(10), dbo.Measurement.PointID) AS ID, dbo.Measurement.SignalID, dbo.Measurement.PointTag, dbo.Measurement.AlternateTag, dbo.Measurement.SignalReference, dbo.Measurement.Internal, dbo.Measurement.Subscribed, dbo.Device.Acronym AS Device, CASE WHEN dbo.Device.IsConcentrator = 0 AND dbo.Device.ParentID IS NOT NULL THEN RuntimeP.ID ELSE dbo.Runtime.ID END AS DeviceID, COALESCE(dbo.Device.FramesPerSecond, 30) AS FramesPerSecond, dbo.Protocol.Acronym AS Protocol, dbo.Protocol.Type AS ProtocolType, dbo.SignalType.Acronym AS SignalType, dbo.SignalType.EngineeringUnits, dbo.Phasor.ID AS PhasorID, dbo.Phasor.Type AS PhasorType, dbo.Phasor.Phase, dbo.Measurement.Adder, dbo.Measurement.Multiplier, dbo.Company.Acronym AS Company, dbo.Device.Longitude, dbo.Device.Latitude, dbo.Measurement.Description, dbo.Measurement.UpdatedOn FROM dbo.Company WITH (NOLOCK) RIGHT OUTER JOIN dbo.Device WITH (NOLOCK) ON dbo.Company.ID = dbo.Device.CompanyID RIGHT OUTER JOIN dbo.Measurement WITH (NOLOCK) LEFT OUTER JOIN dbo.SignalType WITH (NOLOCK) ON dbo.Measurement.SignalTypeID = dbo.SignalType.ID ON dbo.Device.ID = dbo.Measurement.DeviceID LEFT OUTER JOIN dbo.Phasor WITH (NOLOCK) ON dbo.Measurement.DeviceID = dbo.Phasor.DeviceID AND dbo.Measurement.PhasorSourceIndex = dbo.Phasor.SourceIndex LEFT OUTER JOIN dbo.Protocol WITH (NOLOCK) ON dbo.Device.ProtocolID = dbo.Protocol.ID LEFT OUTER JOIN dbo.Historian WITH (NOLOCK) ON dbo.Measurement.HistorianID = dbo.Historian.ID LEFT OUTER JOIN dbo.Runtime WITH (NOLOCK) ON dbo.Device.ID = dbo.Runtime.SourceID AND dbo.Runtime.SourceTable = N'Device' LEFT OUTER JOIN dbo.Runtime AS RuntimeP WITH (NOLOCK) ON RuntimeP.SourceID = dbo.Device.ParentID AND RuntimeP.SourceTable = N'Device' CROSS JOIN dbo.Node WITH (NOLOCK) WHERE (dbo.Device.Enabled <> 0 OR dbo.Device.Enabled IS NULL) AND (dbo.Measurement.Enabled <> 0) UNION ALL SELECT NodeID, SourceNodeID, Source + ':' + CONVERT(NVARCHAR(10), PointID) AS ID, SignalID, PointTag, AlternateTag, SignalReference, 0 AS Internal, 1 AS Subscribed, NULL AS Device, NULL AS DeviceID, FramesPerSecond, ProtocolAcronym AS Protocol, ProtocolType, SignalTypeAcronym AS SignalType, '' AS EngineeringUnits, PhasorID, PhasorType, Phase, Adder, Multiplier, CompanyAcronym AS Company, Longitude, Latitude, Description, getutcdate() AS UpdatedOn FROM dbo.ImportedMeasurement WITH (NOLOCK) WHERE dbo.ImportedMeasurement.Enabled <> 0 GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[RuntimeStatistic] AS SELECT dbo.Node.ID AS NodeID, dbo.Statistic.ID AS ID, dbo.Statistic.Source, dbo.Statistic.SignalIndex, dbo.Statistic.Name, dbo.Statistic.Description, dbo.Statistic.AssemblyName, dbo.Statistic.TypeName, dbo.Statistic.MethodName, dbo.Statistic.Arguments, dbo.Statistic.IsConnectedState, dbo.Statistic.DataType, dbo.Statistic.DisplayFormat, dbo.Statistic.Enabled FROM dbo.Statistic WITH (NOLOCK), dbo.Node WITH (NOLOCK) GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[IaonOutputAdapter] AS SELECT NodeID, ID, AdapterName, AssemblyName, TypeName, ConnectionString FROM dbo.RuntimeHistorian WITH (NOLOCK) UNION SELECT NodeID, ID, AdapterName, AssemblyName, TypeName, ConnectionString FROM dbo.RuntimeCustomOutputAdapter WITH (NOLOCK) GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[IaonInputAdapter] AS SELECT NodeID, ID, AdapterName, AssemblyName, TypeName, ConnectionString FROM dbo.RuntimeDevice WITH (NOLOCK) UNION SELECT NodeID, ID, AdapterName, AssemblyName, TypeName, ConnectionString FROM dbo.RuntimeCustomInputAdapter WITH (NOLOCK) GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[IaonActionAdapter] AS SELECT Node.ID AS NodeID, 0 AS ID, N'PHASOR!SERVICES' AS AdapterName, N'PhasorProtocolAdapters.dll' AS AssemblyName, N'PhasorProtocolAdapters.CommonPhasorServices' AS TypeName, N'' AS ConnectionString FROM dbo.Node WITH (NOLOCK) UNION SELECT NodeID, ID, AdapterName, AssemblyName, TypeName, ConnectionString FROM dbo.RuntimeOutputStream WITH (NOLOCK) UNION SELECT NodeID, ID, AdapterName, AssemblyName, TypeName, ConnectionString FROM dbo.RuntimeCalculatedMeasurement WITH (NOLOCK) UNION SELECT NodeID, ID, AdapterName, AssemblyName, TypeName, ConnectionString FROM dbo.RuntimeCustomActionAdapter WITH (NOLOCK) GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO CREATE VIEW [dbo].[IaonFilterAdapter] AS SELECT NodeID, ID, AdapterName, AssemblyName, TypeName, ConnectionString FROM dbo.RuntimeCustomFilterAdapter WITH (NOLOCK) GO CREATE VIEW [dbo].[HistorianMetadata] AS SELECT HistorianID = PointID, DataType = CASE SignalAcronym WHEN 'DIGI' THEN 1 ELSE 0 END, [Name] = PointTag, Synonym1 = SignalReference, Synonym2 = SignalAcronym, Synonym3 = AlternateTag, Description = Description, HardwareInfo = VendorDeviceDescription, Remarks = '', PlantCode = HistorianAcronym, UnitNumber = 1, SystemName = DeviceAcronym, SourceID = ProtocolID, Enabled = Enabled, ScanRate = 1.0 / FramesPerSecond, CompressionMinTime = 0, CompressionMaxTime = 0, EngineeringUnits = EngineeringUnits, LowWarning = CASE SignalAcronym WHEN 'FREQ' THEN 59.95 WHEN 'VPHM' THEN 475000 WHEN 'IPHM' THEN 0 WHEN 'VPHA' THEN -181 WHEN 'IPHA' THEN -181 ELSE 0 END, HighWarning = CASE SignalAcronym WHEN 'FREQ' THEN 60.05 WHEN 'VPHM' THEN 525000 WHEN 'IPHM' THEN 3150 WHEN 'VPHA' THEN 181 WHEN 'IPHA' THEN 181 ELSE 0 END, LowAlarm = CASE SignalAcronym WHEN 'FREQ' THEN 59.90 WHEN 'VPHM' THEN 450000 WHEN 'IPHM' THEN 0 WHEN 'VPHA' THEN -181 WHEN 'IPHA' THEN -181 ELSE 0 END, HighAlarm = CASE SignalAcronym WHEN 'FREQ' THEN 60.10 WHEN 'VPHM' THEN 550000 WHEN 'IPHM' THEN 3300 WHEN 'VPHA' THEN 181 WHEN 'IPHA' THEN 181 ELSE 0 END, LowRange = CASE SignalAcronym WHEN 'FREQ' THEN 59.95 WHEN 'VPHM' THEN 475000 WHEN 'IPHM' THEN 0 WHEN 'VPHA' THEN -180 WHEN 'IPHA' THEN -180 ELSE 0 END, HighRange = CASE SignalAcronym WHEN 'FREQ' THEN 60.05 WHEN 'VPHM' THEN 525000 WHEN 'IPHM' THEN 3000 WHEN 'VPHA' THEN 180 WHEN 'IPHA' THEN 180 ELSE 0 END, CompressionLimit = 0.0, ExceptionLimit = 0.0, DisplayDigits = CASE SignalAcronym WHEN 'DIGI' THEN 0 ELSE 7 END, SetDescription = '', ClearDescription = '', AlarmState = 0, ChangeSecurity = 5, AccessSecurity = 0, StepCheck = 0, AlarmEnabled = 0, AlarmFlags = 0, AlarmDelay = 0, AlarmToFile = 0, AlarmByEmail = 0, AlarmByPager = 0, AlarmByPhone = 0, AlarmEmails = MeasurementDetail.ContactList, AlarmPagers = '', AlarmPhones = '' FROM [dbo].[MeasurementDetail] WITH (NOLOCK) GO CREATE VIEW [dbo].[CurrentAlarmState] AS SELECT SignalsWithAlarms.SignalID, CurrentState.NewState AS State, CurrentState.Timestamp, CurrentState.Value FROM ( SELECT DISTINCT Measurement.SignalID FROM Measurement JOIN Alarm ON Measurement.SignalID = Alarm.SignalID WHERE Alarm.Enabled <> 0 ) AS SignalsWithAlarms LEFT OUTER JOIN ( SELECT Log1.SignalID, Log1.NewState, Log1.Timestamp, Log1.Value FROM AlarmLog AS Log1 LEFT OUTER JOIN AlarmLog AS Log2 ON Log1.SignalID = Log2.SignalID AND Log1.Ticks < Log2.Ticks WHERE Log2.ID IS NULL ) AS CurrentState ON SignalsWithAlarms.SignalID = CurrentState.SignalID GO CREATE VIEW [dbo].[CalculatedMeasurementDetail] AS SELECT CM.NodeID, CM.ID, CM.Acronym, ISNULL(CM.Name, '') AS Name, CM.AssemblyName, CM.TypeName, ISNULL(CM.ConnectionString, '') AS ConnectionString, ISNULL(CM.ConfigSection, '') AS ConfigSection, ISNULL(CM.InputMeasurements, '') AS InputMeasurements, ISNULL(CM.OutputMeasurements, '') AS OutputMeasurements, CM.MinimumMeasurementsToUse, CM.FramesPerSecond, CM.LagTime, CM.LeadTime, CM.UseLocalClockAsRealTime, CM.AllowSortsByArrival, CM.LoadOrder, CM.Enabled, N.Name AS NodeName, CM.IgnoreBadTimeStamps, CM.TimeResolution, CM.AllowPreemptivePublishing, ISNULL(CM.DownsamplingMethod, '') AS DownsamplingMethod, CM.PerformTimeReasonabilityCheck FROM CalculatedMeasurement CM WITH (NOLOCK), Node N WITH (NOLOCK) WHERE CM.NodeID = N.ID GO CREATE VIEW [dbo].[VendorDeviceDetail] AS SELECT VD.ID, VD.VendorID, VD.Name, ISNULL(VD.Description, '') AS Description, ISNULL(VD.URL, '') AS URL, V.Name AS VendorName, V.Acronym AS VendorAcronym FROM dbo.VendorDevice AS VD WITH (NOLOCK) INNER JOIN dbo.Vendor AS V WITH (NOLOCK) ON VD.VendorID = V.ID GO CREATE VIEW [dbo].[DeviceDetail] AS SELECT D.NodeID, D.ID, D.ParentID, D.UniqueID, D.Acronym, ISNULL(D.Name, '') AS Name, D.OriginalSource, D.IsConcentrator, D.CompanyID, D.HistorianID, D.AccessID, D.VendorDeviceID, D.ProtocolID, D.Longitude, D.Latitude, D.InterconnectionID, ISNULL(D.ConnectionString, '') AS ConnectionString, ISNULL(D.TimeZone, '') AS TimeZone, ISNULL(D.FramesPerSecond, 30) AS FramesPerSecond, D.TimeAdjustmentTicks, D.DataLossInterval, D.ConnectOnDemand, ISNULL(D.ContactList, '') AS ContactList, D.MeasuredLines, D.LoadOrder, D.Enabled, ISNULL(C.Name, '') AS CompanyName, ISNULL(C.Acronym, '') AS CompanyAcronym, ISNULL(C.MapAcronym, '') AS CompanyMapAcronym, ISNULL(H.Acronym, '') AS HistorianAcronym, ISNULL(VD.VendorAcronym, '') AS VendorAcronym, ISNULL(VD.Name, '') AS VendorDeviceName, ISNULL(P.Name, '') AS ProtocolName, P.Type AS ProtocolType, P.Category, ISNULL(I.Name, '') AS InterconnectionName, N.Name AS NodeName, ISNULL(PD.Acronym, '') AS ParentAcronym, D.CreatedOn, D.AllowedParsingExceptions, D.ParsingExceptionWindow, D.DelayedConnectionInterval, D.AllowUseOfCachedConfiguration, D.AutoStartDataParsingSequence, D.SkipDisableRealTimeData, D.MeasurementReportingInterval, D.UpdatedOn FROM dbo.Device AS D WITH (NOLOCK) LEFT OUTER JOIN dbo.Company AS C WITH (NOLOCK) ON C.ID = D.CompanyID LEFT OUTER JOIN dbo.Historian AS H WITH (NOLOCK) ON H.ID = D.HistorianID LEFT OUTER JOIN dbo.VendorDeviceDetail AS VD WITH (NOLOCK) ON VD.ID = D.VendorDeviceID LEFT OUTER JOIN dbo.Protocol AS P WITH (NOLOCK) ON P.ID = D.ProtocolID LEFT OUTER JOIN dbo.Interconnection AS I WITH (NOLOCK) ON I.ID = D.InterconnectionID LEFT OUTER JOIN dbo.Node AS N WITH (NOLOCK) ON N.ID = D.NodeID LEFT OUTER JOIN dbo.Device AS PD WITH (NOLOCK) ON PD.ID = D.ParentID GO CREATE VIEW [dbo].[HistorianDetail] AS SELECT H.NodeID, H.ID, H.Acronym, ISNULL(H.Name, '') AS Name, ISNULL(H.AssemblyName, '') AS AssemblyName, ISNULL(H.TypeName, '') AS TypeName, ISNULL(H.ConnectionString, '') AS ConnectionString, H.IsLocal, ISNULL(H.Description, '') AS Description, H.LoadOrder, H.Enabled, N.Name AS NodeName, H.MeasurementReportingInterval FROM dbo.Historian AS H WITH (NOLOCK) INNER JOIN dbo.Node AS N WITH (NOLOCK) ON H.NodeID = N.ID GO CREATE VIEW [dbo].[NodeDetail] AS SELECT N.ID, N.Name, ISNULL(N.CompanyID, 0) AS CompanyID, ISNULL(N.Longitude, 0) AS Longitude, ISNULL(N.Latitude, 0) AS Latitude, ISNULL(N.Description, '') AS Description, ISNULL(N.ImagePath, '') AS ImagePath, ISNULL(N.Settings, '') AS Settings, N.MenuType, N.MenuData, N.Master, N.LoadOrder, N.Enabled, ISNULL(C.Name, '') AS CompanyName FROM Node N WITH (NOLOCK) LEFT JOIN Company C WITH (NOLOCK) ON N.CompanyID = C.ID GO CREATE VIEW [dbo].[VendorDetail] AS Select ID, ISNULL(Acronym, '') AS Acronym, Name, ISNULL(PhoneNumber, '') AS PhoneNumber, ISNULL(ContactEmail, '') AS ContactEmail, ISNULL(URL, '') AS URL FROM Vendor WITH (NOLOCK) GO CREATE VIEW [dbo].[CustomActionAdapterDetail] AS SELECT CA.NodeID, CA.ID, CA.AdapterName, CA.AssemblyName, CA.TypeName, ISNULL(CA.ConnectionString, '') AS ConnectionString, CA.LoadOrder, CA.Enabled, N.Name AS NodeName FROM dbo.CustomActionAdapter AS CA WITH (NOLOCK) INNER JOIN dbo.Node AS N WITH (NOLOCK) ON CA.NodeID = N.ID GO CREATE VIEW [dbo].[CustomInputAdapterDetail] AS SELECT CA.NodeID, CA.ID, CA.AdapterName, CA.AssemblyName, CA.TypeName, ISNULL(CA.ConnectionString, '') AS ConnectionString, CA.LoadOrder, CA.Enabled, N.Name AS NodeName FROM dbo.CustomInputAdapter AS CA WITH (NOLOCK) INNER JOIN dbo.Node AS N WITH (NOLOCK) ON CA.NodeID = N.ID GO CREATE VIEW [dbo].[CustomOutputAdapterDetail] AS SELECT CA.NodeID, CA.ID, CA.AdapterName, CA.AssemblyName, CA.TypeName, ISNULL(CA.ConnectionString, '') AS ConnectionString, CA.LoadOrder, CA.Enabled, N.Name AS NodeName FROM dbo.CustomOutputAdapter AS CA WITH (NOLOCK) INNER JOIN dbo.Node AS N WITH (NOLOCK) ON CA.NodeID = N.ID GO CREATE VIEW [dbo].[CustomFilterAdapterDetail] AS SELECT CA.NodeID, CA.ID, CA.AdapterName, CA.AssemblyName, CA.TypeName, ISNULL(CA.ConnectionString, '') AS ConnectionString, CA.LoadOrder, CA.Enabled, N.Name AS NodeName FROM dbo.CustomFilterAdapter AS CA WITH (NOLOCK) INNER JOIN dbo.Node AS N WITH (NOLOCK) ON CA.NodeID = N.ID GO CREATE VIEW [dbo].[IaonTreeView] AS SELECT 'Action Adapters' AS AdapterType, NodeID, ID, AdapterName, AssemblyName, TypeName, ISNULL(ConnectionString, '') AS ConnectionString FROM dbo.IaonActionAdapter WITH (NOLOCK) UNION ALL SELECT 'Input Adapters' AS AdapterType, NodeID, ID, AdapterName, AssemblyName, TypeName, ISNULL(ConnectionString, '') AS ConnectionString FROM dbo.IaonInputAdapter WITH (NOLOCK) UNION ALL SELECT 'Output Adapters' AS AdapterType, NodeID, ID, AdapterName, AssemblyName, TypeName, ISNULL(ConnectionString, '') AS ConnectionString FROM dbo.IaonOutputAdapter WITH (NOLOCK) UNION ALL SELECT 'Filter Adapters' AS AdapterType, NodeID, ID, AdapterName, AssemblyName, TypeName, ISNULL(ConnectionString, '') AS ConnectionString FROM dbo.IaonFilterAdapter WITH (NOLOCK) GO CREATE VIEW [dbo].[OtherDeviceDetail] AS SELECT OD.ID, OD.Acronym, ISNULL(OD.Name, '') AS Name, OD.IsConcentrator, OD.CompanyID, OD.VendorDeviceID, OD.Longitude, OD.Latitude, OD.InterconnectionID, OD.Planned, OD.Desired, OD.InProgress, ISNULL(C.Name, '') AS CompanyName, ISNULL(C.Acronym, '') AS CompanyAcronym, ISNULL(C.MapAcronym, '') AS CompanyMapAcronym, ISNULL(VD.Name, '') AS VendorDeviceName, ISNULL(I.Name, '') AS InterconnectionName FROM dbo.OtherDevice AS OD WITH (NOLOCK) LEFT OUTER JOIN dbo.Company AS C WITH (NOLOCK) ON OD.CompanyID = C.ID LEFT OUTER JOIN dbo.VendorDevice AS VD WITH (NOLOCK) ON OD.VendorDeviceID = VD.ID LEFT OUTER JOIN dbo.Interconnection AS I WITH (NOLOCK) ON OD.InterconnectionID = I.ID GO CREATE VIEW [dbo].[MapData] AS SELECT 'Device' AS DeviceType, NodeID, ID, Acronym, ISNULL(Name, '') AS Name, CompanyMapAcronym, CompanyName, VendorDeviceName, Longitude, Latitude, CONVERT(BIT, '1') AS Reporting, CONVERT(BIT, '0') AS Inprogress, CONVERT(BIT, '0') AS Planned, CONVERT(BIT, '0') AS Desired FROM dbo.DeviceDetail AS D WITH (NOLOCK) UNION ALL SELECT 'OtherDevice' AS DeviceType, NULL AS NodeID, ID, Acronym, ISNULL(Name, '') AS Name, CompanyMapAcronym, CompanyName, VendorDeviceName, Longitude, Latitude, CONVERT(BIT, '0') AS Reporting, CONVERT(BIT, '1') AS Inprogress, CONVERT(BIT, '1') AS Planned, CONVERT(BIT, '1') AS Desired FROM dbo.OtherDeviceDetail AS OD WITH (NOLOCK) GO CREATE VIEW [dbo].[VendorDeviceDistribution] AS SELECT dbo.Device.NodeID, dbo.Vendor.Name AS VendorName, COUNT(*) AS DeviceCount FROM dbo.Device WITH (NOLOCK) LEFT OUTER JOIN dbo.VendorDevice WITH (NOLOCK) ON dbo.Device.VendorDeviceID = dbo.VendorDevice.ID INNER JOIN dbo.Vendor WITH (NOLOCK) ON dbo.VendorDevice.VendorID = dbo.Vendor.ID GROUP BY dbo.Device.NodeID, dbo.Vendor.Name GO CREATE VIEW [dbo].[OutputStreamDetail] AS SELECT OS.NodeID, OS.ID, OS.Acronym, ISNULL(OS.Name, '') AS Name, OS.Type, ISNULL(OS.ConnectionString, '') AS ConnectionString, OS.IDCode, ISNULL(OS.CommandChannel, '') AS CommandChannel, ISNULL(OS.DataChannel, '') AS DataChannel, OS.AutoPublishConfigFrame, OS.AutoStartDataChannel, OS.NominalFrequency, OS.FramesPerSecond, OS.LagTime, OS.LeadTime, OS.UseLocalClockAsRealTime, OS.AllowSortsByArrival, OS.LoadOrder, OS.Enabled, N.Name AS NodeName, OS.DigitalMaskValue, OS.AnalogScalingValue, OS.VoltageScalingValue, OS.CurrentScalingValue, OS.CoordinateFormat, OS.DataFormat, OS.DownsamplingMethod, OS.AllowPreemptivePublishing, OS.TimeResolution, OS.IgnoreBadTimeStamps, OS.PerformTimeReasonabilityCheck FROM dbo.OutputStream AS OS WITH (NOLOCK) INNER JOIN dbo.Node AS N WITH (NOLOCK) ON OS.NodeID = N.ID GO CREATE VIEW [dbo].[OutputStreamMeasurementDetail] AS SELECT OSM.NodeID, OSM.AdapterID, OSM.ID, OSM.HistorianID, OSM.PointID, OSM.SignalReference, M.PointTag AS SourcePointTag, ISNULL(H.Acronym, '') AS HistorianAcronym FROM dbo.OutputStreamMeasurement AS OSM WITH (NOLOCK) INNER JOIN dbo.Measurement AS M WITH (NOLOCK) ON M.PointID = OSM.PointID LEFT OUTER JOIN dbo.Historian AS H WITH (NOLOCK) ON H.ID = OSM.HistorianID GO CREATE VIEW [dbo].[OutputStreamDeviceDetail] AS SELECT NodeID, AdapterID, ID, Acronym, ISNULL(BpaAcronym, '') AS BpaAcronym, Name, LoadOrder, Enabled, ISNULL(PhasorDataFormat, '') AS PhasorDataFormat, ISNULL(FrequencyDataFormat, '') AS FrequencyDataFormat, ISNULL(AnalogDataFormat, '') AS AnalogDataFormat, ISNULL(CoordinateFormat, '') AS CoordinateFormat, IDCode, CASE WHEN EXISTS (SELECT Acronym FROM Device WITH (NOLOCK) WHERE Acronym = OSD.Acronym) THEN CONVERT(bit, 0) ELSE CONVERT(bit, 1) END AS Virtual FROM dbo.OutputStreamDevice AS OSD WITH (NOLOCK) GO CREATE VIEW [dbo].[PhasorDetail] AS SELECT P.*, ISNULL(DP.Label, '') AS DestinationPhasorLabel, D.Acronym AS DeviceAcronym FROM Phasor P WITH (NOLOCK) LEFT OUTER JOIN Phasor DP WITH (NOLOCK) ON P.DestinationPhasorID = DP.ID LEFT OUTER JOIN Device D WITH (NOLOCK) ON P.DeviceID = D.ID GO CREATE VIEW [dbo].[StatisticMeasurement] AS SELECT * FROM MeasurementDetail WITH (NOLOCK) WHERE SignalAcronym = 'STAT' GO CREATE VIEW [dbo].[SubscriberMeasurementDetail] AS SELECT SubscriberMeasurement.NodeID AS NodeID, SubscriberMeasurement.SubscriberID AS SubscriberID, Subscriber.Acronym AS SubscriberAcronym, COALESCE(Subscriber.Name, '') AS SubscriberName, SubscriberMeasurement.SignalID AS SignalID, SubscriberMeasurement.Allowed AS Allowed, Measurement.PointID AS PointID, Measurement.PointTag AS PointTag, Measurement.SignalReference AS SignalReference FROM ((SubscriberMeasurement WITH (NOLOCK) JOIN Subscriber WITH (NOLOCK) ON (SubscriberMeasurement.SubscriberID = Subscriber.ID)) JOIN Measurement WITH (NOLOCK) ON (SubscriberMeasurement.SignalID = Measurement.SignalID)); GO CREATE VIEW [dbo].[SubscriberMeasGroupDetail] AS SELECT SubscriberMeasurementGroup.NodeID AS NodeID, SubscriberMeasurementGroup.SubscriberID AS SubscriberID, Subscriber.Acronym AS SubscriberAcronym, COALESCE(Subscriber.Name, '') AS SubscriberName, SubscriberMeasurementGroup.MeasurementGroupID AS MeasurementGroupID, SubscriberMeasurementGroup.Allowed AS Allowed, MeasurementGroup.Name AS MeasurementGroupName FROM ((SubscriberMeasurementGroup WITH (NOLOCK) JOIN Subscriber WITH (NOLOCK) ON (SubscriberMeasurementGroup.SubscriberID = Subscriber.ID)) JOIN MeasurementGroup WITH (NOLOCK) ON (SubscriberMeasurementGroup.MeasurementGroupID = MeasurementGroup.ID)); GO CREATE VIEW [dbo].[MeasurementGroupMeasDetail] AS SELECT MeasurementGroupMeasurement.MeasurementGroupID AS MeasurementGroupID, MeasurementGroup.Name AS MeasurementGroupName, MeasurementGroupMeasurement.SignalID AS SignalID, Measurement.PointID AS PointID, Measurement.PointTag AS PointTag, Measurement.SignalReference AS SignalReference FROM ((MeasurementGroupMeasurement WITH (NOLOCK) JOIN MeasurementGroup WITH (NOLOCK) ON (MeasurementGroupMeasurement.MeasurementGroupID = MeasurementGroup.ID)) JOIN Measurement WITH (NOLOCK) ON (MeasurementGroupMeasurement.SignalID = Measurement.SignalID)); GO CREATE VIEW [dbo].[TrackedTable] AS SELECT 'Measurement' AS Name UNION SELECT 'ActiveMeasurement' AS Name UNION SELECT 'Device' AS Name UNION SELECT 'OutputStream' AS Name UNION SELECT 'OutputStreamDevice' AS Name UNION SELECT 'OutputStreamMeasurement' AS Name GO ALTER TABLE [dbo].[OtherDevice] WITH CHECK ADD CONSTRAINT [FK_OtherDevice_Company] FOREIGN KEY([CompanyID]) REFERENCES [dbo].[Company] ([ID]) GO ALTER TABLE [dbo].[OtherDevice] WITH CHECK ADD CONSTRAINT [FK_OtherDevice_Interconnection] FOREIGN KEY([InterconnectionID]) REFERENCES [dbo].[Interconnection] ([ID]) GO ALTER TABLE [dbo].[OtherDevice] WITH CHECK ADD CONSTRAINT [FK_OtherDevice_VendorDevice] FOREIGN KEY([VendorDeviceID]) REFERENCES [dbo].[VendorDevice] ([ID]) GO ALTER TABLE [dbo].[Node] WITH CHECK ADD CONSTRAINT [FK_Node_Company] FOREIGN KEY([CompanyID]) REFERENCES [dbo].[Company] ([ID]) GO ALTER TABLE [dbo].[DataOperation] WITH CHECK ADD CONSTRAINT [FK_DataOperation_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[Device] WITH CHECK ADD CONSTRAINT [FK_Device_Company] FOREIGN KEY([CompanyID]) REFERENCES [dbo].[Company] ([ID]) GO ALTER TABLE [dbo].[Device] WITH CHECK ADD CONSTRAINT [FK_Device_Device] FOREIGN KEY([ParentID]) REFERENCES [dbo].[Device] ([ID]) GO ALTER TABLE [dbo].[Device] WITH CHECK ADD CONSTRAINT [FK_Device_Interconnection] FOREIGN KEY([InterconnectionID]) REFERENCES [dbo].[Interconnection] ([ID]) GO ALTER TABLE [dbo].[Device] WITH CHECK ADD CONSTRAINT [FK_Device_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) GO ALTER TABLE [dbo].[Device] WITH CHECK ADD CONSTRAINT [FK_Device_Protocol] FOREIGN KEY([ProtocolID]) REFERENCES [dbo].[Protocol] ([ID]) GO ALTER TABLE [dbo].[Device] WITH CHECK ADD CONSTRAINT [FK_Device_VendorDevice] FOREIGN KEY([VendorDeviceID]) REFERENCES [dbo].[VendorDevice] ([ID]) GO ALTER TABLE [dbo].[VendorDevice] WITH CHECK ADD CONSTRAINT [FK_VendorDevice_Vendor] FOREIGN KEY([VendorID]) REFERENCES [dbo].[Vendor] ([ID]) GO ALTER TABLE [dbo].[OutputStreamDeviceDigital] WITH CHECK ADD CONSTRAINT [FK_OutputStreamDeviceDigital_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) GO ALTER TABLE [dbo].[OutputStreamDeviceDigital] WITH CHECK ADD CONSTRAINT [FK_OutputStreamDeviceDigital_OutputStreamDevice] FOREIGN KEY([OutputStreamDeviceID]) REFERENCES [dbo].[OutputStreamDevice] ([ID]) ON DELETE CASCADE GO ALTER TABLE [dbo].[OutputStreamDevicePhasor] WITH CHECK ADD CONSTRAINT [FK_OutputStreamDevicePhasor_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) GO ALTER TABLE [dbo].[OutputStreamDevicePhasor] WITH CHECK ADD CONSTRAINT [FK_OutputStreamDevicePhasor_OutputStreamDevice] FOREIGN KEY([OutputStreamDeviceID]) REFERENCES [dbo].[OutputStreamDevice] ([ID]) ON DELETE CASCADE GO ALTER TABLE [dbo].[OutputStreamDeviceAnalog] WITH CHECK ADD CONSTRAINT [FK_OutputStreamDeviceAnalog_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) GO ALTER TABLE [dbo].[OutputStreamDeviceAnalog] WITH CHECK ADD CONSTRAINT [FK_OutputStreamDeviceAnalog_OutputStreamDevice] FOREIGN KEY([OutputStreamDeviceID]) REFERENCES [dbo].[OutputStreamDevice] ([ID]) ON DELETE CASCADE GO ALTER TABLE [dbo].[Measurement] WITH CHECK ADD CONSTRAINT [FK_Measurement_Device] FOREIGN KEY([DeviceID]) REFERENCES [dbo].[Device] ([ID]) GO ALTER TABLE [dbo].[Measurement] WITH CHECK ADD CONSTRAINT [FK_Measurement_SignalType] FOREIGN KEY([SignalTypeID]) REFERENCES [dbo].[SignalType] ([ID]) GO ALTER TABLE [dbo].[ImportedMeasurement] WITH CHECK ADD CONSTRAINT [FK_ImportedMeasurement_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[OutputStreamMeasurement] WITH CHECK ADD CONSTRAINT [FK_OutputStreamMeasurement_Historian] FOREIGN KEY([HistorianID]) REFERENCES [dbo].[Historian] ([ID]) GO ALTER TABLE [dbo].[OutputStreamMeasurement] WITH CHECK ADD CONSTRAINT [FK_OutputStreamMeasurement_Measurement] FOREIGN KEY([PointID]) REFERENCES [dbo].[Measurement] ([PointID]) GO ALTER TABLE [dbo].[OutputStreamMeasurement] WITH CHECK ADD CONSTRAINT [FK_OutputStreamMeasurement_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) GO ALTER TABLE [dbo].[OutputStreamMeasurement] WITH CHECK ADD CONSTRAINT [FK_OutputStreamMeasurement_OutputStream] FOREIGN KEY([AdapterID]) REFERENCES [dbo].[OutputStream] ([ID]) ON DELETE CASCADE GO ALTER TABLE [dbo].[OutputStreamDevice] WITH CHECK ADD CONSTRAINT [FK_OutputStreamDevice_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) GO ALTER TABLE [dbo].[OutputStreamDevice] WITH CHECK ADD CONSTRAINT [FK_OutputStreamDevice_OutputStream] FOREIGN KEY([AdapterID]) REFERENCES [dbo].[OutputStream] ([ID]) ON DELETE CASCADE GO ALTER TABLE [dbo].[Phasor] WITH CHECK ADD CONSTRAINT [FK_Phasor_Device] FOREIGN KEY([DeviceID]) REFERENCES [dbo].[Device] ([ID]) ON DELETE CASCADE GO ALTER TABLE [dbo].[Phasor] WITH CHECK ADD CONSTRAINT [FK_Phasor_Phasor] FOREIGN KEY([DestinationPhasorID]) REFERENCES [dbo].[Phasor] ([ID]) GO ALTER TABLE [dbo].[CalculatedMeasurement] WITH CHECK ADD CONSTRAINT [FK_CalculatedMeasurement_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[CustomActionAdapter] WITH CHECK ADD CONSTRAINT [FK_CustomActionAdapter_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[Historian] WITH CHECK ADD CONSTRAINT [FK_Historian_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[CustomInputAdapter] WITH CHECK ADD CONSTRAINT [FK_CustomInputAdapter_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[CustomFilterAdapter] WITH CHECK ADD CONSTRAINT [FK_CustomFilterAdapter_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[OutputStream] WITH CHECK ADD CONSTRAINT [FK_OutputStream_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE [dbo].[Alarm] WITH CHECK ADD CONSTRAINT [FK_Alarm_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) GO ALTER TABLE [dbo].[Alarm] WITH CHECK ADD CONSTRAINT [FK_Alarm_Measurement_SignalID] FOREIGN KEY([SignalID]) REFERENCES [dbo].[Measurement] ([SignalID]) GO ALTER TABLE [dbo].[Alarm] WITH CHECK ADD CONSTRAINT [FK_Alarm_Measurement_AssociatedMeasurementID] FOREIGN KEY([SignalID]) REFERENCES [dbo].[Measurement] ([SignalID]) GO ALTER TABLE [dbo].[AlarmLog] WITH CHECK ADD CONSTRAINT [FK_AlarmLog_Measurement] FOREIGN KEY([SignalID]) REFERENCES [dbo].[Measurement] ([SignalID]) GO ALTER TABLE [dbo].[AlarmLog] WITH CHECK ADD CONSTRAINT [FK_AlarmLog_Alarm_PreviousState] FOREIGN KEY([PreviousState]) REFERENCES [dbo].[Alarm] ([ID]) GO ALTER TABLE [dbo].[AlarmLog] WITH CHECK ADD CONSTRAINT [FK_AlarmLog_Alarm_NewState] FOREIGN KEY([NewState]) REFERENCES [dbo].[Alarm] ([ID]) GO ALTER TABLE [dbo].[CustomOutputAdapter] WITH CHECK ADD CONSTRAINT [FK_CustomOutputAdapter_Node] FOREIGN KEY([NodeID]) REFERENCES [dbo].[Node] ([ID]) ON UPDATE CASCADE ON DELETE CASCADE GO -- Triggers to clear references on delete. -- SQL Server is strangely picky about cyclic cascade paths and multiple -- cascade paths so triggers must be used instead of ON DELETE CASCADE. CREATE TRIGGER [dbo].[Node_ClearReferences] ON [dbo].[Node] INSTEAD OF DELETE AS BEGIN DELETE FROM Alarm WHERE NodeID IN (SELECT ID FROM deleted) DELETE FROM Node WHERE ID IN (SELECT ID FROM deleted) END GO CREATE TRIGGER [dbo].[Measurement_ClearReferences] ON [dbo].[Measurement] INSTEAD OF DELETE AS BEGIN SET NOCOUNT ON; DELETE FROM [dbo].[PowerCalculation] WHERE [ApparentPowerOutputSignalID] IN (SELECT [SignalID] FROM DELETED) OR [CurrentAngleSignalID] IN (SELECT [SignalID] FROM DELETED) OR [CurrentMagSignalID] IN (SELECT [SignalID] FROM DELETED) OR [ReactivePowerOutputSignalID] IN (SELECT [SignalID] FROM DELETED) OR [ActivePowerOutputSignalID] IN (SELECT [SignalID] FROM DELETED) OR [VoltageAngleSignalID] IN (SELECT [SignalID] FROM DELETED) OR [VoltageMagSignalID] IN (SELECT [SignalID] FROM DELETED) DELETE FROM [dbo].[MeasurementGroupMeasurement] WHERE [SignalID] IN (SELECT [SignalID] FROM DELETED) DELETE FROM [dbo].[SubscriberMeasurement] WHERE [SignalID] IN (SELECT [SignalID] FROM DELETED) DELETE FROM [dbo].[OutputStreamMeasurement] WHERE [PointID] IN (SELECT [PointID] FROM DELETED) DELETE FROM [dbo].[AlarmLog] WHERE [SignalID] IN (SELECT [SignalID] FROM DELETED) DELETE FROM [dbo].[Alarm] WHERE [SignalID] IN (SELECT [SignalID] FROM DELETED) OR [AssociatedMeasurementID] IN (SELECT [SignalID] FROM DELETED) DELETE FROM [dbo].[Measurement] WHERE [SignalID] IN (SELECT [SignalID] FROM DELETED) END GO CREATE TRIGGER [dbo].[Device_ClearReferences] ON [dbo].[Device] INSTEAD OF DELETE AS BEGIN DELETE FROM Measurement WHERE DeviceID IN (SELECT ID FROM deleted) DELETE FROM Device WHERE ID IN (SELECT ID FROM deleted) END GO CREATE TRIGGER [dbo].[Alarm_ClearReferences] ON [dbo].[Alarm] INSTEAD OF DELETE AS BEGIN DELETE FROM AlarmLog WHERE PreviousState IN (SELECT ID FROM deleted) OR NewState IN (SELECT ID FROM deleted) DELETE FROM Alarm WHERE ID IN (SELECT ID FROM deleted) END GO -- *********************** -- Company Change Tracking -- *********************** CREATE TRIGGER [dbo].[Company_UpdateTracker] ON [dbo].[Company] AFTER UPDATE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; SELECT inserted.Acronym INTO #acronym FROM inserted INNER JOIN deleted ON inserted.ID = deleted.ID WHERE inserted.Acronym <> deleted.Acronym INSERT INTO TrackedChange(TableName, PrimaryKeyColumn, PrimaryKeyValue) SELECT 'ActiveMeasurement', 'SignalID', SignalID FROM ActiveMeasurement INNER JOIN #acronym a ON ActiveMeasurement.Company = a.Acronym DROP TABLE #acronym END GO -- ********************** -- Device Change Tracking -- ********************** CREATE TRIGGER [dbo].[Device_UpdateTracker] ON [dbo].[Device] AFTER INSERT, UPDATE, DELETE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; -- Track changes made to the Device table SELECT ID INTO #deviceUpdate FROM inserted UNION SELECT ID FROM deleted INSERT INTO TrackedChange(TableName, PrimaryKeyColumn, PrimaryKeyValue) SELECT 'Device', 'ID', ID FROM #deviceUpdate DROP TABLE #deviceUpdate -- Track changes made to the ActiveMeasurement view SELECT inserted.ID INTO #activeMeasurementUpdate FROM inserted INNER JOIN deleted ON inserted.ID = deleted.ID WHERE inserted.NodeID <> deleted.NodeID OR inserted.Acronym <> deleted.Acronym OR inserted.IsConcentrator <> deleted.IsConcentrator OR (inserted.ParentID IS NULL AND deleted.ParentID IS NOT NULL) OR (inserted.ParentID IS NOT NULL AND deleted.ParentID IS NULL) OR (inserted.ParentID IS NOT NULL AND deleted.ParentID IS NOT NULL AND inserted.ParentID <> deleted.ParentID) OR (inserted.FramesPerSecond IS NULL AND deleted.FramesPerSecond IS NOT NULL) OR (inserted.FramesPerSecond IS NOT NULL AND deleted.FramesPerSecond IS NULL) OR (inserted.FramesPerSecond IS NOT NULL AND deleted.FramesPerSecond IS NOT NULL AND inserted.FramesPerSecond <> deleted.FramesPerSecond) OR (inserted.Longitude IS NULL AND deleted.Longitude IS NOT NULL) OR (inserted.Longitude IS NOT NULL AND deleted.Longitude IS NULL) OR (inserted.Longitude IS NOT NULL AND deleted.Longitude IS NOT NULL AND inserted.Longitude <> deleted.Longitude) OR (inserted.Latitude IS NULL AND deleted.Latitude IS NOT NULL) OR (inserted.Latitude IS NOT NULL AND deleted.Latitude IS NULL) OR (inserted.Latitude IS NOT NULL AND deleted.Latitude IS NOT NULL AND inserted.Latitude <> deleted.Latitude) OR (inserted.CompanyID IS NULL AND deleted.CompanyID IS NOT NULL) OR (inserted.CompanyID IS NOT NULL AND deleted.CompanyID IS NULL) OR (inserted.CompanyID IS NOT NULL AND deleted.CompanyID IS NOT NULL AND inserted.CompanyID <> deleted.CompanyID) OR (inserted.ProtocolID IS NULL AND deleted.ProtocolID IS NOT NULL) OR (inserted.ProtocolID IS NOT NULL AND deleted.ProtocolID IS NULL) OR (inserted.ProtocolID IS NOT NULL AND deleted.ProtocolID IS NOT NULL AND inserted.ProtocolID <> deleted.ProtocolID) OR inserted.Enabled <> deleted.Enabled INSERT INTO TrackedChange(TableName, PrimaryKeyColumn, PrimaryKeyValue) SELECT 'ActiveMeasurement', 'SignalID', SignalID FROM Measurement INNER JOIN #activeMeasurementUpdate am ON Measurement.DeviceID = am.ID DROP TABLE #activeMeasurementUpdate END GO -- ************************* -- Historian Change Tracking -- ************************* CREATE TRIGGER [dbo].[Historian_UpdateTracker] ON [dbo].[Historian] AFTER UPDATE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; SELECT inserted.ID INTO #historianID FROM inserted INNER JOIN deleted ON inserted.ID = deleted.ID WHERE inserted.NodeID <> deleted.NodeID OR inserted.Acronym <> deleted.Acronym INSERT INTO TrackedChange(TableName, PrimaryKeyColumn, PrimaryKeyValue) SELECT 'ActiveMeasurement', 'SignalID', SignalID FROM Measurement INNER JOIN #historianID h ON Measurement.HistorianID = h.ID DROP TABLE #historianID END GO -- *************************** -- Measurement Change Tracking -- *************************** CREATE TRIGGER [dbo].[Measurement_UpdateTracker] ON [dbo].[Measurement] AFTER INSERT, UPDATE, DELETE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; SELECT PointID INTO #pointID FROM inserted UNION SELECT PointID FROM deleted INSERT INTO TrackedChange(TableName, PrimaryKeyColumn, PrimaryKeyValue) SELECT 'Measurement', 'PointID', PointID FROM #pointID DROP TABLE #pointID SELECT SignalID INTO #signalID FROM inserted UNION SELECT SignalID FROM deleted INSERT INTO TrackedChange(TableName, PrimaryKeyColumn, PrimaryKeyValue) SELECT 'ActiveMeasurement', 'SignalID', SignalID FROM #signalID DROP TABLE #signalID END GO -- **************************** -- OutputStream Change Tracking -- **************************** CREATE TRIGGER [dbo].[OutputStream_UpdateTracker] ON [dbo].[OutputStream] AFTER INSERT, UPDATE, DELETE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; SELECT ID INTO #outputStreamID FROM inserted UNION SELECT ID FROM deleted INSERT INTO TrackedChange(TableName, PrimaryKeyColumn, PrimaryKeyValue) SELECT 'OutputStream', 'ID', ID FROM #outputStreamID DROP TABLE #outputStreamID END GO -- ********************************** -- OutputStreamDevice Change Tracking -- ********************************** CREATE TRIGGER [dbo].[OutputStreamDevice_UpdateTracker] ON [dbo].[OutputStreamDevice] AFTER INSERT, UPDATE, DELETE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; SELECT ID INTO #outputStreamDeviceID FROM inserted UNION SELECT ID FROM deleted INSERT INTO TrackedChange(TableName, PrimaryKeyColumn, PrimaryKeyValue) SELECT 'OutputStreamDevice', 'ID', ID FROM #outputStreamDeviceID DROP TABLE #outputStreamDeviceID END GO -- *************************************** -- OutputStreamMeasurement Change Tracking -- *************************************** CREATE TRIGGER [dbo].[OutputStreamMeasurement_UpdateTracker] ON [dbo].[OutputStreamMeasurement] AFTER INSERT, UPDATE, DELETE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; SELECT ID INTO #outputStreamMeasurementID FROM inserted UNION SELECT ID FROM deleted INSERT INTO TrackedChange(TableName, PrimaryKeyColumn, PrimaryKeyValue) SELECT 'OutputStreamMeasurement', 'ID', ID FROM #outputStreamMeasurementID DROP TABLE #outputStreamMeasurementID END GO -- ********************** -- Phasor Change Tracking -- ********************** CREATE TRIGGER [dbo].[Phasor_UpdateTracker] ON [dbo].[Phasor] AFTER UPDATE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; SELECT inserted.ID INTO #phasorID FROM inserted INNER JOIN deleted ON inserted.ID = deleted.ID WHERE inserted.Type <> deleted.Type OR inserted.Phase <> deleted.Phase SELECT inserted.DeviceID AS NewDeviceID, inserted.SourceIndex AS NewSourceIndex, deleted.DeviceID AS OldDeviceID, deleted.SourceIndex AS OldSourceIndex INTO #phasorKey FROM inserted INNER JOIN deleted ON inserted.ID = deleted.ID WHERE inserted.DeviceID <> deleted.DeviceID OR inserted.SourceIndex <> deleted.SourceIndex INSERT INTO TrackedChange(TableName, PrimaryKeyColumn, PrimaryKeyValue) SELECT 'ActiveMeasurement', 'SignalID', SignalID FROM ActiveMeasurement INNER JOIN #phasorID p ON ActiveMeasurement.PhasorID = p.ID INSERT INTO TrackedChange(TableName, PrimaryKeyColumn, PrimaryKeyValue) SELECT 'ActiveMeasurement', 'SignalID', SignalID FROM Measurement INNER JOIN #phasorKey p ON (Measurement.DeviceID = p.NewDeviceID AND Measurement.PhasorSourceIndex = p.NewSourceIndex) OR (Measurement.DeviceID = p.OldDeviceID AND Measurement.PhasorSourceIndex = p.OldSourceIndex) DROP TABLE #phasorID DROP TABLE #phasorKey END GO -- ************************ -- Protocol Change Tracking -- ************************ CREATE TRIGGER [dbo].[Protocol_UpdateTracker] ON [dbo].[Protocol] AFTER UPDATE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; SELECT inserted.Acronym INTO #acronym FROM inserted INNER JOIN deleted ON inserted.ID = deleted.ID WHERE inserted.Acronym <> deleted.Acronym OR inserted.Type <> deleted.Type INSERT INTO TrackedChange(TableName, PrimaryKeyColumn, PrimaryKeyValue) SELECT 'ActiveMeasurement', 'SignalID', SignalID FROM ActiveMeasurement INNER JOIN #acronym a ON ActiveMeasurement.Protocol = a.Acronym DROP TABLE #acronym END GO -- ************************** -- SignalType Change Tracking -- ************************** CREATE TRIGGER [dbo].[SignalType_UpdateTracker] ON [dbo].[SignalType] AFTER UPDATE AS BEGIN -- SET NOCOUNT ON added to prevent extra result sets from -- interfering with SELECT statements. SET NOCOUNT ON; SELECT inserted.ID INTO #signalTypeID FROM inserted INNER JOIN deleted ON inserted.ID = deleted.ID WHERE inserted.Acronym <> deleted.Acronym INSERT INTO TrackedChange(TableName, PrimaryKeyColumn, PrimaryKeyValue) SELECT 'ActiveMeasurement', 'SignalID', SignalID FROM Measurement INNER JOIN #signalTypeID s ON Measurement.SignalTypeID = s.ID DROP TABLE #signalTypeID END GO --SET ANSI_NULLS ON --GO --SET QUOTED_IDENTIFIER ON --GO --CREATE PROCEDURE [GetFormattedMeasurements] -- @measurementSql NVARCHAR(max), -- @includeAdjustments BIT, -- @measurements NVARCHAR(max) OUTPUT --AS -- -- Fill the table variable with the rows for your result set -- DECLARE @measurementID INT -- DECLARE @archiveSource NVARCHAR(50) -- DECLARE @adder FLOAT -- DECLARE @multiplier FLOAT -- SET @measurements = '' -- CREATE TABLE #temp -- ( -- [MeasurementID] INT, -- [ArchiveSource] NVARCHAR(50), -- [Adder] FLOAT, -- [Multiplier] FLOAT -- ) -- INSERT INTO #temp EXEC sp_executesql @measurementSql -- DECLARE SelectedMeasurements CURSOR LOCAL FAST_FORWARD FOR SELECT * FROM #temp -- OPEN SelectedMeasurements -- -- Get first row from measurements SQL -- FETCH NEXT FROM SelectedMeasurements INTO @measurementID, @archiveSource, @adder, @multiplier -- -- Step through selected measurements -- WHILE @@FETCH_STATUS = 0 -- BEGIN -- IF LEN(@measurements) > 0 -- SET @measurements = @measurements + ';' -- IF @includeAdjustments <> 0 AND (@adder <> 0.0 OR @multiplier <> 1.0) -- SET @measurements = @measurements + @archiveSource + ':' + @measurementID + ',' + @adder + ',' + @multiplier -- ELSE -- SET @measurements = @measurements + @archiveSource + ':' + @measurementID -- -- Get next row from measurements SQL -- FETCH NEXT FROM SelectedMeasurements INTO @measurementID, @archiveSource, @adder, @multiplier -- END -- CLOSE SelectedMeasurements -- DEALLOCATE SelectedMeasurements -- DROP TABLE #temp --GO --SET ANSI_NULLS ON --GO --SET QUOTED_IDENTIFIER ON --GO --CREATE FUNCTION [FormatMeasurements] (@measurementSql NVARCHAR(max), @includeAdjustments BIT) --RETURNS NVARCHAR(max) --AS --BEGIN -- DECLARE @measurements NVARCHAR(max) -- SET @measurements = '' -- EXEC GetFormattedMeasurements @measurementSql, @includeAdjustments, @measurements -- IF LEN(@measurements) > 0 -- SET @measurements = '{' + @measurements + '}' -- ELSE -- SET @measurements = NULL -- RETURN @measurements --END --GO -- ************************** -- Alarm Panel Data -- ************************** CREATE TABLE AlarmState( ID INT IDENTITY(1,1) NOT NULL PRIMARY KEY, State VARCHAR(50) NULL, Color VARCHAR(50) NULL, RecommendedAction VARCHAR(500) NULL ) GO CREATE TABLE AlarmDevice( ID INT IDENTITY(1,1) NOT NULL PRIMARY KEY, DeviceID INT NULL, StateID INT NULL, TimeStamp DATETIME NULL, DisplayData VARCHAR(10) NULL ) GO ALTER TABLE AlarmDevice ADD CONSTRAINT [FK_AlarmDevice_Device] FOREIGN KEY(DeviceID) REFERENCES Device(ID) ON UPDATE CASCADE ON DELETE CASCADE GO ALTER TABLE AlarmDevice ADD CONSTRAINT [FK_AlarmDevice_AlarmState] FOREIGN KEY(StateID) REFERENCES AlarmState(ID) ON UPDATE CASCADE ON DELETE CASCADE GO CREATE VIEW AlarmDeviceStateView AS SELECT AlarmDevice.ID, Device.Name, AlarmState.State, AlarmState.Color, AlarmDevice.DisplayData, Device.ID AS DeviceID FROM AlarmDevice INNER JOIN AlarmState ON AlarmDevice.StateID = AlarmState.ID INNER JOIN Device ON AlarmDevice.DeviceID = Device.ID GO -- ******************************************************************************************* -- IMPORTANT NOTE: When making updates to this schema, please increment the version number! -- ******************************************************************************************* CREATE VIEW [dbo].[LocalSchemaVersion] AS SELECT 3 AS VersionNumber GO CREATE TABLE DataAvailability( ID INT IDENTITY(1,1) NOT NULL PRIMARY KEY, GoodAvailableData FLOAT NOT NULL, BadAvailableData FLOAT NOT NULL, TotalAvailableData FLOAT NOT NULL, ) GO