OneSecondDataWindowAdapterBase Properties

Properties

AllowPreemptivePublishing Gets or sets flag that allows system to preemptively publish frames assuming all ExpectedMeasurements have arrived.
(Inherited from ConcentratorBase)
AllowSortsByArrival Gets or sets flag that determines whether or not to allow incoming measurements with bad timestamps to be sorted by arrival time.
(Inherited from ConcentratorBase)
AutoStart Gets or sets flag indicating if adapter should automatically start or otherwise connect on demand.
(Inherited from ActionAdapterBase)
AveragePublicationTimePerFrame Gets the average required frame publication time, in seconds.
(Inherited from ConcentratorBase)
ConnectionInfo Gets connection info for adapter, if any.
(Inherited from ActionAdapterBase)
ConnectionString Gets or sets key/value pair connection information specific to action adapter.
(Inherited from ActionAdapterBase)
DataSource Gets or sets DataSet based data source available to this ActionAdapterBase.
(Inherited from ActionAdapterBase)
DiscardedMeasurements Gets the total number of measurements that have been discarded because of old timestamps (i.e., measurements that were outside the time deviation tolerance from base time, past or future).
(Inherited from ConcentratorBase)
DownsampledMeasurements Gets the total number of down-sampled measurements processed by the concentrator.
(Inherited from ConcentratorBase)
DownsamplingMethod Gets or sets the DownsamplingMethod to be used by the concentrator.
(Inherited from ConcentratorBase)
Enabled Gets or sets the current enabled state of concentrator.
(Inherited from ConcentratorBase)
ExpectedMeasurements Gets or sets the expected number of measurements to be assigned to a single frame.
(Inherited from ConcentratorBase)
FramesAheadOfSchedule Gets the total number of frames ahead of schedule processed by the concentrator.
(Inherited from ConcentratorBase)
FramesPerSecond Gets or sets the number of frames per second.
(Inherited from ActionAdapterBase)
ID Gets or sets numeric ID associated with this action adapter.
(Inherited from ActionAdapterBase)
IgnoreBadTimestamps Gets or sets flag that determines if bad timestamps (as determined by measurement's timestamp quality) should be ignored when sorting measurements.
(Inherited from ConcentratorBase)
InitializationTimeout Gets or sets maximum time system will wait during Start for initialization.
(Inherited from ActionAdapterBase)
Initialized Gets or sets flag indicating if the action adapter has been initialized successfully.
(Inherited from ActionAdapterBase)
InputCount Gets or sets the expected number of input measurements for a OneSecondDataWindowAdapterBase instance.
InputMeasurementKeys Gets or sets primary keys of input measurements the action adapter expects.
(Overrides ActionAdapterBaseInputMeasurementKeys)
InputMeasurementKeyTypes Gets or sets input measurement SignalType's for each of the InputMeasurementKeys, if any.
InputSourceIDs Gets or sets Source values used to filter input measurement keys.
(Inherited from ActionAdapterBase)
IsDisposed Gets a flag that indicates whether the object has been disposed.
(Inherited from ActionAdapterBase)
LagTicks Gets defined past time deviation tolerance, in ticks.
(Inherited from ConcentratorBase)
LagTime Gets or sets the allowed past-time deviation tolerance, in seconds (can be sub-second).
(Inherited from ActionAdapterBase)
LastDiscardedMeasurement Gets a reference the last IMeasurement that was discarded by the concentrator.
(Inherited from ConcentratorBase)
LastDiscardedMeasurementLatency Gets the calculated latency of the last IMeasurement that was discarded by the concentrator.
(Inherited from ConcentratorBase)
LastFrame Gets reference to the last published IFrame.
(Inherited from ConcentratorBase)
LatestMeasurements Gets reference to the collection of absolute latest received measurement values.
(Inherited from ConcentratorBase)
LeadTime Gets or sets the allowed future time deviation tolerance, in seconds (can be sub-second).
(Inherited from ActionAdapterBase)
Log Log messages generated by an adapter.
(Inherited from ConcentratorBase)
MaximumPublicationTimeout Gets or sets the maximum frame publication timeout in milliseconds, set to Infinite(-1) to wait indefinitely.
(Inherited from ConcentratorBase)
MeasurementsSortedByArrival Gets the total number of measurements that were sorted by arrival because the measurement reported a bad timestamp quality.
(Inherited from ConcentratorBase)
MinimumMeasurementsToUse Gets or sets minimum number of input measurements required for adapter. Set to -1 to require all.
(Inherited from ActionAdapterBase)
MissedSortsByTimeout Gets the total number of missed sorts by timeout processed by the concentrator.
(Inherited from ConcentratorBase)
Name Gets name of the action adapter.
(Inherited from ActionAdapterBase)
OutputCount Gets or sets the expected number of output measurements for a OneSecondDataWindowAdapterBase instance.
OutputMeasurements Gets or sets output measurements that the action adapter will produce, if any.
(Overrides ActionAdapterBaseOutputMeasurements)
OutputMeasurementTypes Gets or sets output measurement SignalType's for each of the OutputMeasurements, if any.
OutputSourceIDs Gets or sets Source values used to filter output measurements.
(Inherited from ActionAdapterBase)
PerformTimestampReasonabilityCheck Gets or sets flag that determines if timestamp reasonability checks should be performed on incoming measurements (i.e., measurement timestamps are compared to system clock for reasonability using LeadTime tolerance).
(Inherited from ConcentratorBase)
ProcessByReceivedTimestamp Gets or sets flag that determines if concentrator should sort measurements by received time.
(Inherited from ConcentratorBase)
ProcessedMeasurements Gets the total number of measurements successfully sorted.
(Inherited from ConcentratorBase)
ProcessingInterval Gets or sets the desired processing interval, in milliseconds, for the adapter.
(Inherited from ConcentratorBase)
PublishedFrames Gets the total number of published frames.
(Inherited from ConcentratorBase)
PublishedMeasurements Gets the total number of published measurements.
(Inherited from ConcentratorBase)
QueueState Gets detailed state of concentrator frame queue.
(Inherited from ConcentratorBase)
RealTime Gets the most accurate time value that is available. If UseLocalClockAsRealTime = true, then this function will return UtcNow. Otherwise, this function will return the timestamp of the most recent measurement, or UtcNow if no measurement timestamps are within time deviation tolerances as specified by the LeadTime value.
(Inherited from ConcentratorBase)
ReceivedMeasurements Gets the total number of measurements ever requested for sorting.
(Inherited from ConcentratorBase)
RequestedInputMeasurementKeys Gets or sets input measurement keys that are requested by other adapters based on what adapter says it can provide.
(Inherited from ActionAdapterBase)
RequestedOutputMeasurementKeys Gets or sets output measurement keys that are requested by other adapters based on what adapter says it can provide.
(Inherited from ActionAdapterBase)
RespectInputDemands Gets or sets flag indicating if action adapter should respect auto-start requests based on input demands.
(Inherited from ActionAdapterBase)
RespectOutputDemands Gets or sets flag indicating if action adapter should respect auto-start requests based on output demands.
(Inherited from ActionAdapterBase)
RoundToNearestTimestamp Gets or sets a value to indicate whether the concentrator should round to the nearest frame timestamp rather than rounding down to the nearest timestamps.
(Inherited from ConcentratorBase)
RunTime Gets the total amount of time, in seconds, that the concentrator has been active.
(Inherited from ConcentratorBase)
Settings Gets settings DictionaryTKey, TValue parsed when ConnectionString was assigned.
(Inherited from ActionAdapterBase)
ShowConcentratorStatus Gets flags that determines if ConcentratorBase class status should be included in ActionAdapterBase status.
(Inherited from ActionAdapterBase)
SourceMeasurementTable Gets or sets the source measurement table to use for configuration.
StartTime Gets the UTC time the concentrator was started.
(Inherited from ConcentratorBase)
StartTimeConstraint Gets the start time temporal processing constraint defined by call to SetTemporalConstraint(String, String, String).
(Inherited from ActionAdapterBase)
Status Returns the detailed status of the OneSecondDataWindowAdapterBase.
(Overrides ActionAdapterBaseStatus)
StopTime Gets the UTC time the concentrator was stopped.
(Inherited from ConcentratorBase)
StopTimeConstraint Gets the stop time temporal processing constraint defined by call to SetTemporalConstraint(String, String, String).
(Inherited from ActionAdapterBase)
SubsecondOffsets Gets sub-second offsets based on current FramesPerSecond.
SupportsTemporalProcessing Gets the flag indicating if this adapter supports temporal processing.
(Overrides ActionAdapterBaseSupportsTemporalProcessing)
TicksPerFrame Gets the number of ticks per frame.
(Inherited from ConcentratorBase)
TimeResolution Gets or sets the maximum time resolution, in ticks, to use when sorting measurements by timestamps into their proper destination frame.
(Inherited from ConcentratorBase)
TotalPublicationTime Gets the total number of seconds frames have spent in the publication process since concentrator started.
(Inherited from ConcentratorBase)
TrackLatestMeasurements Gets or sets flag to start tracking the absolute latest received measurement values.
(Inherited from ConcentratorBase)
UseLocalClockAsRealTime Gets or sets flag that determines whether or not to use the local clock time as real-time.
(Inherited from ConcentratorBase)
UsePrecisionTimer Gets or sets flag that determines if precision timer should be used for frame publication.
(Inherited from ConcentratorBase)
WaitHandleExpirations Gets the total number of wait handle expirations encountered due to delayed precision timer releases.
(Inherited from ConcentratorBase)

See Also